VOL stands for voltage. Requires 1 to 5 voltage values to be input one by one.
example:"1" on the screen represents the first voltage, and "
changed through the
【
UP
】
and
【
setting. After the 5 power values are set, long press
setting interface.
8.3 PAS Parameter Setting
8.3.1 PAS Level Selection
SCA stands for PAS parameter setting.
In the PAS level selection, there are 8 modes:
【
DOWN
】
, short press
【
MODE
】
to confirm, enter the corresponding
8.3.2 PAS Ratio Value Setting
By setting the PAS ratio value, the speed of each level can be adjusted, to meet the needs of different cyclists.
Take the first level as an example, “30-
current value of the first level (ie 40% output).
【
MODE
】
to confirm and enter the next
to the display personalized setting interface.
8.4 Current Limit Value Setting
CUR stands for current limit. The current limit can be set in the range of 7.0
change the max current of controller. Long press
setting interface. The default value is 15A.
KING-METER TECHNOLOGY
No.15, Chenchang Road, Beichen Dist.Tianjin,300134,CN
Fax
:
+0086 022 8478 0358
12
r voltage. Requires 1 to 5 voltage values to be input one by one. Take the first power value as an
"1" on the screen represents the first voltage, and "28.0" is the first power value. The value can be
【
DOWN
】
. Short press
【
MODE
】
to confirm and enter the next power value
setting. After the 5 power values are set, long press
【
MODE
】
to confirm, and return to the
In the PAS level selection, there are 8 modes: 0-3, 1-3, 0-5, 1-5, 0-7, 1-7, 0-9, 1-9. Switch between
to confirm, enter the corresponding PAS ratio value setting interface.
setting the PAS ratio value, the speed of each level can be adjusted, to meet the needs of different cyclists.
-50” is the recommended range of the first level PAS ratio, and
% output). Set by
【
UP
】
and
【
DOWN
】
to increase/decrease
to confirm and enter the next PAS ratio setting. After setting, long press
【
MODE
setting interface.
Current Limit Value Setting
current limit can be set in the range of 7.0-18.0A. Use
【
change the max current of controller. Long press
【
MODE
】
to confirm and return to the display
setting interface. The default value is 15A.
METER TECHNOLOGY CO., LTD
No.15, Chenchang Road, Beichen Dist.Tianjin,300134,CN
+0086 022 8478 0358 Tel: +0086 022 8478
Take the first power value as an
" is the first power value. The value can be
d enter the next power value
to confirm, and return to the display personalized
9. Switch between
【
UP
】
and
ratio value setting interface.
setting the PAS ratio value, the speed of each level can be adjusted, to meet the needs of different cyclists.
is the recommended range of the first level PAS ratio, and “40” is the
to increase/decrease. Short press
MODE
】
to confirm and return
【
UP
】
and
【
DOWN
】
to
to confirm and return to the display personalized