It is possible to connect flashing light devices to the “LAMP” input (terminals 8,9). These devices turn on a second before the 

manoeuvre. If the dip 5 “LAMP” is ON position, the power supplied is intermittent. Therefore, a normal lamp can be connected. If 

the dip 5 “LAMP” is OFF position, the power supplied is direct. Therefore the terminals must be connected to a flashing light with 

a built-in oscillating circuit. 

12 - OTHER CONNECTABLE ACCESSORIES 

13 - BUILT-IN MODULES

It is possible to manage an electro lock (maximum power 15W) using an accessory card 

12D - ELECTRO LOCK (OPTIONAL CARD) 

12A - FLASHING LAMP 

- Check the presence of voltage in the terminals of the external fuse box.

- Check the fuse (see paragraph 1A).

- STOP contact open (red led “ST” is off): check for possible STOP commands connected (terminal 14). If absent, connect the 

input with terminal 14.

14A - THE AUTOMATION DOESN’T START 

-The photocell is obstructed (red led “PHO” is off): check the correct positioning of the photocells and their range. 

-The photocell is absent (red led “PHO” is off): if there are no devices connected on terminal 16, jumper the input. 

-A normally closed contact, or a defective contact, is connected on “STAR” input (terminal 12 – the green led “START” is steady 

on). 

 

14B - THE AUTOMATION PERFORMS ONLY THE OPENING CYCLE 

- The radio transmitter hasn’t been correctly programmed (see paragraph 3). 

- The battery of the transmitter are exhaust. Change them. 

14C - THE AUTOMATION WORKS ONLY BY WIRE 

- The automatic reclosing dip “AUTO” is ON. Put the dip in OFF (see paragraph 4A). 

- The rapid reclosing dip “FAST” is ON. Put the dip in OFF (see paragraph 4A) 

14D - THE AUTOMATIONS CLOSES WITHOUT EXTERNAL COMMANDS 

- Not enough power. Set “FOR” trimmer at maximum level, and program the automation again (see paragraph 4B). Perform a 

professional programming procedure (paragraph 5D) and reduce at minimum (or remove) the slowdowns. 

14F - THE AUTOMATION STARTS BUT, AT A CERTAIN POINT, IT STOPS 

- An external antenna has been connected, but the standard cable mounted in the control unit hasn’t been removed. Remove 

the cable. 

- The battery of the transmitter are exhaust. Change them. 

- There are external interferences. Install an external antenna. 

 

 

14G - LIMITED SEGNAL RECEPTION

- Too low obstacle sensitivity. Increase the “OBS” trimmer (see paragraph 4B). 

- Check the motors: they should turn off some seconds after the beat. In case, lower the OBS trimmer (see paragraph 4B), and 

perform the programming procedure again. 

- Intervention of safety devices. If there are two pairs of photocells, they could see each other. Invert a receiver with its transmit-

ter (see paragraph 11A). 

14E - THE AUTOMATION STARTS BUT, AT A CERTAIN POINT, IT INVERTS THE TRAVEL

     

The lamp must be 24 Vdc, and power rating must not be greater than 15W. 

14 - INCONVENIENTS AND REMEDIES 

It is possible to connect a radio frequency antenna to the “ANT” input (terminals 1,2). The control unit is provided with a 

pre-connected cable. In particular environmental conditions, it can be useful to connect an external antenna, to increase the 

transmitter range.

12B - ANTENNA 

     In case of connection of external antennas, it is necessary to remove the pre-connected cable.

If the safety device self-test is not used (see paragraph 11C), the output “+TX” (terminal 20) acts as a gate open warning light. 

The status of the lamp is as follows: 

- If the access is closed the light is switched off 

- If the access is open is alight with a fixed light 

- If the access is opening the lamp flashes. 

- If the access is closing the lamp flashes quickly. 

12C - OPENED GATE WARNING LIGHT 

     The warning light must be 12 Vdc and it can’t be more than 3W.

     If the electro lock is connected, it could be necessary to set the dip 6 “Strike” to ON position, to have a stroke 

reversing pulse at the beginning of the opening, and at the end of the closing.

!

It is possible to connect two 12Vdc batteries in series (or one 24Vdc battery), max 7Ah, using a battery charge card 

12E - BUFFER BATTERIES (OPTIONAL CARD)

     The quantity of cycles achievable with batteries depends on the power of the motors, and on the Ah of the batteries.

!

Thanks to an optional card (“Selc 12”), it is possible to manage a courtesy light (230Vac, max 500W). The output contact is free, 

and it is provided before every manoeuvre for a customizable time from 0 to 120 seconds.

12F - COURTESY LIGHT (OPTIONAL CARD)

“MEMO 200” module is a memory card (see paragraph 1A) which stores the radio transmitters codes 

(see paragraph 3A and/or 3B).

13A - “MEMO” MODULE

The “RX STAR” module is necessary to receive the radio transmitters frequencies (433.920 MHz).

It doesn’t contain the radio codes.

13B - “RX STAR” MODULE

- Increase the “OBS” trimmer, in order to push more the wings against the mechanical stop and perform the programming 

procedure again.  

14H - THE WINGS, IN CLOSING POSITION, ARE NOT BLOCKED ENOUGH 

- The mechanism is too stressed in closing position. Decrease the “OBS” trimmer, and perform the programming procedure 

again.  

14I - THE MANUAL RELEASE IS TOO HARD

- Perform a programming procedure (see paragraph 6B or 6D). Then try again. 

 

 

14L - THE RED LED “ERR” TURNS ON, AND THE CONTROL UNIT DOES NOT ACCEPT INPUT

Summary of Contents for Star MM 224

Page 1: ...Star MM 224 MiniModus INSTRUCTION MANUAL EN...

Page 2: ...gramming buttons Dip switch function setting Paragraph 4A 5 MEMO Extractable memory Paragraph 13A External Power connection fuse box RX Star radio code receiver 433 920MHz Paragraph 13B Setting trimme...

Page 3: ...izable delay between the wings in closing from 0 to 15 sec by trimmer see paragraph 4B Pause time before automatic reclosing customizable from 0 to 90 sec by trimmer see paragraph 4B Sensibility of th...

Page 4: ...n the other one MOT1 terminal 24 25 must start first Then it will be necessary to regulate the delay between the wings through the trimmer DEL see paragraph 4B If there is only 1 motor connected it mu...

Page 5: ...RADIO again to exit the procedure red LED goes off 3B PEDESTRIAN OPENING START CHANNEL PROGRAMMING PROCEDURE Using this procedure the installer can delete all the previously programmed radio remote c...

Page 6: ...equires the repetition of the learning procedure point 2 because of the change of the manoeuvre time The slowdowns are automatically set in the last 15 of the travel 4B TRIMMER SETTINGS 4A DIP SWITCHE...

Page 7: ...vene stop the motion of the wings which will open again as soon as cleared typical functioning of the photocell If the PHO2 dip switch is set to OFF the safety devices in opening when they intervene i...

Page 8: ...programming procedure verify that The motors shut down a few seconds after the end of the programming procedure The control unit respond to the inputs received by wire START terminal 12 pedestrian ope...

Page 9: ...remote control for the second wing 12a Choose the point of slow down with the button SET or the button 1 of the transmitter for the first wing and with the button RADIO or the button 2 of the remote c...

Page 10: ...by wire the START button or a button in the transmitter 5 The gate begins to open 6 Press the command by wire the START button or the button in the transmitter to set the widening of the pedestrian o...

Page 11: ...is equal to about 0 1 seconds if adjusted to an intermediate position it is equal to about 1 5 seconds while at the maximum the intervention time will be about 3 seconds See also paragraph 11D 8C Tri...

Page 12: ...closing commands neither automatic nor by wire as long as the contact will be opened again The pedestrian opening is a partial opening or total opening if the installer wants it of the wing opened by...

Page 13: ...urrent 11D OBSTACLE DETECTION BY POWER ABSORPTION The control unit has a self test function of the safeties connected to the PHO1 and PHO2 input It switches off the transmitter to check the commutatio...

Page 14: ...gate open warning light The status of the lamp is as follows If the access is closed the light is switched off If the access is open is alight with a fixed light If the access is opening the lamp fla...

Page 15: ...procedure paragraph 5D and reduce at minimum or remove the slowdowns 14F THE AUTOMATION STARTS BUT AT A CERTAIN POINT IT STOPS An external antenna has been connected but the standard cable mounted in...

Page 16: ...King Gates S r l Via A Malignani 42 33077 Sacile PN ITALY Tel 39 0434 737082 Fax 39 0434 785351 e mail info king gates com web www king gates com MADE IN ITALY...

Reviews: