It is possible to connect flashing light devices to the “LAMP” input (terminals 8,9). These devices turn on a second before the
manoeuvre. If the dip 5 “LAMP” is ON position, the power supplied is intermittent. Therefore, a normal lamp can be connected. If
the dip 5 “LAMP” is OFF position, the power supplied is direct. Therefore the terminals must be connected to a flashing light with
a built-in oscillating circuit.
12 - OTHER CONNECTABLE ACCESSORIES
13 - BUILT-IN MODULES
It is possible to manage an electro lock (maximum power 15W) using an accessory card
12D - ELECTRO LOCK (OPTIONAL CARD)
12A - FLASHING LAMP
- Check the presence of voltage in the terminals of the external fuse box.
- Check the fuse (see paragraph 1A).
- STOP contact open (red led “ST” is off): check for possible STOP commands connected (terminal 14). If absent, connect the
input with terminal 14.
14A - THE AUTOMATION DOESN’T START
-The photocell is obstructed (red led “PHO” is off): check the correct positioning of the photocells and their range.
-The photocell is absent (red led “PHO” is off): if there are no devices connected on terminal 16, jumper the input.
-A normally closed contact, or a defective contact, is connected on “STAR” input (terminal 12 – the green led “START” is steady
on).
14B - THE AUTOMATION PERFORMS ONLY THE OPENING CYCLE
- The radio transmitter hasn’t been correctly programmed (see paragraph 3).
- The battery of the transmitter are exhaust. Change them.
14C - THE AUTOMATION WORKS ONLY BY WIRE
- The automatic reclosing dip “AUTO” is ON. Put the dip in OFF (see paragraph 4A).
- The rapid reclosing dip “FAST” is ON. Put the dip in OFF (see paragraph 4A)
14D - THE AUTOMATIONS CLOSES WITHOUT EXTERNAL COMMANDS
- Not enough power. Set “FOR” trimmer at maximum level, and program the automation again (see paragraph 4B). Perform a
professional programming procedure (paragraph 5D) and reduce at minimum (or remove) the slowdowns.
14F - THE AUTOMATION STARTS BUT, AT A CERTAIN POINT, IT STOPS
- An external antenna has been connected, but the standard cable mounted in the control unit hasn’t been removed. Remove
the cable.
- The battery of the transmitter are exhaust. Change them.
- There are external interferences. Install an external antenna.
14G - LIMITED SEGNAL RECEPTION
- Too low obstacle sensitivity. Increase the “OBS” trimmer (see paragraph 4B).
- Check the motors: they should turn off some seconds after the beat. In case, lower the OBS trimmer (see paragraph 4B), and
perform the programming procedure again.
- Intervention of safety devices. If there are two pairs of photocells, they could see each other. Invert a receiver with its transmit-
ter (see paragraph 11A).
14E - THE AUTOMATION STARTS BUT, AT A CERTAIN POINT, IT INVERTS THE TRAVEL
The lamp must be 24 Vdc, and power rating must not be greater than 15W.
14 - INCONVENIENTS AND REMEDIES
!
It is possible to connect a radio frequency antenna to the “ANT” input (terminals 1,2). The control unit is provided with a
pre-connected cable. In particular environmental conditions, it can be useful to connect an external antenna, to increase the
transmitter range.
12B - ANTENNA
In case of connection of external antennas, it is necessary to remove the pre-connected cable.
!
If the safety device self-test is not used (see paragraph 11C), the output “+TX” (terminal 20) acts as a gate open warning light.
The status of the lamp is as follows:
- If the access is closed the light is switched off
- If the access is open is alight with a fixed light
- If the access is opening the lamp flashes.
- If the access is closing the lamp flashes quickly.
12C - OPENED GATE WARNING LIGHT
The warning light must be 12 Vdc and it can’t be more than 3W.
!
If the electro lock is connected, it could be necessary to set the dip 6 “Strike” to ON position, to have a stroke
reversing pulse at the beginning of the opening, and at the end of the closing.
!
It is possible to connect two 12Vdc batteries in series (or one 24Vdc battery), max 7Ah, using a battery charge card
12E - BUFFER BATTERIES (OPTIONAL CARD)
The quantity of cycles achievable with batteries depends on the power of the motors, and on the Ah of the batteries.
!
Thanks to an optional card (“Selc 12”), it is possible to manage a courtesy light (230Vac, max 500W). The output contact is free,
and it is provided before every manoeuvre for a customizable time from 0 to 120 seconds.
12F - COURTESY LIGHT (OPTIONAL CARD)
“MEMO 200” module is a memory card (see paragraph 1A) which stores the radio transmitters codes
(see paragraph 3A and/or 3B).
13A - “MEMO” MODULE
The “RX STAR” module is necessary to receive the radio transmitters frequencies (433.920 MHz).
It doesn’t contain the radio codes.
13B - “RX STAR” MODULE
- Increase the “OBS” trimmer, in order to push more the wings against the mechanical stop and perform the programming
procedure again.
14H - THE WINGS, IN CLOSING POSITION, ARE NOT BLOCKED ENOUGH
- The mechanism is too stressed in closing position. Decrease the “OBS” trimmer, and perform the programming procedure
again.
14I - THE MANUAL RELEASE IS TOO HARD
- Perform a programming procedure (see paragraph 6B or 6D). Then try again.
14L - THE RED LED “ERR” TURNS ON, AND THE CONTROL UNIT DOES NOT ACCEPT INPUT