The installer can set the beginning point of the slowdown through this procedure. The beginning point is
customizable in opening and closing.
6D - PROFESSIONAL LEARNING PROCEDURE
After the programming procedure, see also paragraph 6C for the starting.
!
1.
Place the wings in
middle position.
2. RESET
: push the
SET
button for
2 seconds.
3.
The yellow led
flashes.
4.
Push the
RADIO
button
for
1 second
within 5
seconds (the yellow led
switches on).
9b.
Intervention of the
mechanical stop
or of the electric limit
switch.
End of opening.
12b.
Mechanical stop
intervention or of
the electric limit switch.
End of closing.
8.
Do you want
deceleration during
opening?
11.
Do you want
deceleration during
closing?
9a.
Choose the point of slow-down
with the button SET or the button 1
of the transmitter for the first wing,
and with the button RADIO or the
button 2 of the remote control
for the second wing.
12a.
Choose the point of slow-down
with the button SET or the button
1 of the transmitter for the first
wing, and with the button RADIO
or the button 2 of the remote
control for the second wing.
7.
Push
SET
button or a button
of the radio transmitter.
The control unit performs
the opening.
END
of learning
(yellow led turns off)
5.
The control unit perform a little
opening cycle at low speed (if the
motors go in the opposite direction,
invert the motor phases and the
eventual limit switches phases.
6.
It closes the first wing,
and then it closes the second
wing. Intervention of the
mechanical stop or the electric
limit switch. End of closing.
10.
Push
SET
button or a
button of the radio transmitter.
The control unit performs the
closing.
NO
YES
YES
NO
The installer set the manoeuvre time and the workforce of the motors by this procedure
- In the absence of electric limit switches, or to having a better travel regulation, it could be necessary to intervene
during the programming procedure, at the end of opening and closing cycles (points 6, 7, 8 for the standard
programming procedure, and points 6, 9B, 12B for the professional programming procedure), by pushing the SET
button for the wing 1, and RADIO for the wing 2, to stop them at the end of the opening/closing.
- In case of 1 motor only, it must be connected to “MOT1” (terminals 24-25), and the delay between the wings
(trimmer “
DEL
”) must be set to 0.
It is necessary to perform the learning procedure to program the travel (see paragraph 6B for the standard proce-
dure, or paragraph 6D for the professional procedure). There is also a learning procedure for the pedestrian
opening (see paragraph 6E; it is not indispensable).
The control unit is programmed by the buttons, and the control unit status is shown during the programming
procedure by the yellow led “SET”. When the control unit begins the programming procedure, the yellow led “SET”
switches on. It stays on until the end of the programming procedure, or until an anticipated quit (by pushing SET
and RADIO simultaneously), which stops the programming procedure and the motors.
6 - TRAVEL PROGRAMMING PROCEDURE
6A - PROGRAMMING WARNINGS
After the programming procedure verify that:
- The motors shut down a few seconds after the end of the programming procedure.
- The control unit respond to the inputs received by wire: “
START
” (terminal 12), pedestrian opening (terminal 15),
and “
STOP
” (terminal 14).
- The control unit respond to the inputs received by transmitter.
- The safety devices connected to “
PHO1
” (terminal 16) intervene while the gate is closing and prevent the closing
when the gate is opened.
- The safety devices connected to “
PHO2
” (terminal 17) intervene while the gate is open and that they prevent the
opening when the gate is closed. If the DIP “PHO2” is set to ON, to intervene while the gate is closing and prevent
the closing when the gate is opened.
6C - WARNINGS BEFORE STARTING
6B - STANDARD LEARNING PROCEDURE
During the programming procedure, every safety device is disabled, to let the installer moving through
their range.
!
1.
Put the wings in a
middle position.
2. RESET
: push the
SET
button for
2 seconds.
3.
The yellow led
flashes.
4.
Push the
SET
button
for
1 second
within 5
seconds (the yellow led
switches on).
END
of the learning
procedure.
5.
The control unit perform a little
opening cycle at low speed (if the
motors go in the opposite direction,
invert the motor phases and the
eventual limit switches phases).
6.
It closes the first wing,
and then it closes the second
wing. Intervention of the
mechanical stop or the electric
limit switch. End of closing.
8.
It closes. Intervention
of the mechanical stop
or the electric limit switch.
End of closing.
7.
It opens. Intervention
of the mechanical stop
or the electric limit switch.
End of opening.
On steps 9a and 12a of the programming procedure, the first wing is the one which opens as first and
closes as second (connected to terminals 24, 25 “MOT1”).
The second wing, instead, is the one which opens as second and closes as first (connected to terminals
26, 27 “MOT2”).
!