background image

The installer can set the beginning point of the slowdown through this procedure. The beginning point is  

customizable in opening and closing. 

6D - PROFESSIONAL LEARNING PROCEDURE 

     After the programming procedure, see also paragraph 6C for the starting. 

1.

 Place the wings in  

middle position. 

2. RESET

: push the 

SET 

button for 

2 seconds.

3.

 The yellow led  

flashes. 

4.

 Push the 

RADIO

 button

for 

1 second

 within 5 

seconds (the yellow led 

switches on).

9b. 

Intervention of the 

mechanical stop 

or of the electric limit 

switch. 

End of opening. 

12b. 

Mechanical stop  

intervention or of  

the electric limit switch.  

End of closing. 

8.

 Do you want  

deceleration during  

opening? 

11.

 Do you want  

deceleration during  

closing? 

9a. 

Choose the point of slow-down 

with the button SET or the button 1 

of the transmitter for the first wing, 

and with the button RADIO or the 

button 2 of the remote control 

for the second wing.

12a.

 

Choose the point of slow-down 

with the button SET or the button

1 of the transmitter for the first 

wing, and with the button RADIO

or the button 2 of the remote

control for the second wing.

7. 

Push 

SET

 button or a button

of the radio transmitter.

The control unit performs

the opening.

END 

of learning  

(yellow led turns off) 

5.

The control unit perform a little 

opening cycle at low speed (if the 

motors go in the opposite direction, 

invert the motor phases and the 

eventual limit switches phases. 

6.

 It closes the first wing, 

and then it closes the second 

wing. Intervention of the 

mechanical stop or the electric 

limit switch. End of closing. 

10.

 Push 

SET

 button or a 

button of the radio transmitter. 

The control unit performs the 

closing.

NO 

YES 

YES 

NO 

The installer set the manoeuvre time and the workforce of the motors by this procedure 

- In the absence of electric limit switches, or to having a better travel regulation, it could be necessary to intervene 

during the programming procedure, at the end of opening and closing cycles (points 6, 7, 8 for the standard 

programming procedure, and points 6, 9B, 12B for the professional programming procedure), by pushing the SET 

button for the wing 1, and RADIO for the wing 2, to stop them at the end of the opening/closing.

- In case of 1 motor only, it must be connected to “MOT1” (terminals 24-25), and the delay between the wings 

(trimmer “

DEL

”) must be set to 0.

It is necessary to perform the learning procedure to program the travel (see paragraph 6B for the standard proce-

dure, or paragraph 6D for the professional procedure). There is also a learning procedure for the pedestrian 

opening (see paragraph 6E; it is not indispensable).

The control unit is programmed by the buttons, and the control unit status is shown during the programming 

procedure by the yellow led “SET”. When the control unit begins the programming procedure, the yellow led “SET” 

switches on. It stays on until the end of the programming procedure, or until an anticipated quit (by pushing SET 

and RADIO simultaneously), which stops the programming procedure and the motors.

6 - TRAVEL PROGRAMMING PROCEDURE 

6A - PROGRAMMING WARNINGS  

After the programming procedure verify that: 

- The motors shut down a few seconds after the end of the programming procedure. 

- The control unit respond to the inputs received by wire: “

START

” (terminal 12), pedestrian opening (terminal 15), 

and “

STOP

” (terminal 14). 

- The control unit respond to the inputs received by transmitter. 

- The safety devices connected to “

PHO1

” (terminal 16) intervene while the gate is closing and prevent the closing 

when the gate is opened. 

- The safety devices connected to “

PHO2

” (terminal 17) intervene while the gate is open and that they prevent the 

opening when the gate is closed. If the DIP “PHO2” is set to ON, to intervene while the gate is closing and prevent 

the closing when the gate is opened. 

6C - WARNINGS BEFORE STARTING 

6B - STANDARD LEARNING PROCEDURE 

     During the programming procedure, every safety device is disabled, to let the installer moving through 

their range. 

1.

 Put the wings in a 

middle position. 

2. RESET

: push the 

SET 

button for 

2 seconds.

3.

 The yellow led  

flashes. 

4.

 Push the 

SET

 button

for 

1 second

 within 5 

seconds (the yellow led 

switches on).

END 

of the learning 

procedure. 

5.

The control unit perform a little 

opening cycle at low speed (if the 

motors go in the opposite direction, 

invert the motor phases and the 

eventual limit switches phases). 

6.

 It closes the first wing, 

and then it closes the second 

wing. Intervention of the 

mechanical stop or the electric 

limit switch. End of closing. 

8.

 It closes. Intervention 

of the mechanical stop 

or the electric limit switch. 

End of closing. 

7.

 It opens. Intervention 

of the mechanical stop 

or the electric limit switch. 

End of opening. 

     On steps 9a and 12a of the programming procedure, the first wing is the one which opens as first and 

closes as second (connected to terminals 24, 25 “MOT1”). 

The second wing, instead, is the one which opens as second and closes as first (connected to terminals 

26, 27 “MOT2”). 

Summary of Contents for Star MM 224

Page 1: ...Star MM 224 MiniModus INSTRUCTION MANUAL EN...

Page 2: ...gramming buttons Dip switch function setting Paragraph 4A 5 MEMO Extractable memory Paragraph 13A External Power connection fuse box RX Star radio code receiver 433 920MHz Paragraph 13B Setting trimme...

Page 3: ...izable delay between the wings in closing from 0 to 15 sec by trimmer see paragraph 4B Pause time before automatic reclosing customizable from 0 to 90 sec by trimmer see paragraph 4B Sensibility of th...

Page 4: ...n the other one MOT1 terminal 24 25 must start first Then it will be necessary to regulate the delay between the wings through the trimmer DEL see paragraph 4B If there is only 1 motor connected it mu...

Page 5: ...RADIO again to exit the procedure red LED goes off 3B PEDESTRIAN OPENING START CHANNEL PROGRAMMING PROCEDURE Using this procedure the installer can delete all the previously programmed radio remote c...

Page 6: ...equires the repetition of the learning procedure point 2 because of the change of the manoeuvre time The slowdowns are automatically set in the last 15 of the travel 4B TRIMMER SETTINGS 4A DIP SWITCHE...

Page 7: ...vene stop the motion of the wings which will open again as soon as cleared typical functioning of the photocell If the PHO2 dip switch is set to OFF the safety devices in opening when they intervene i...

Page 8: ...programming procedure verify that The motors shut down a few seconds after the end of the programming procedure The control unit respond to the inputs received by wire START terminal 12 pedestrian ope...

Page 9: ...remote control for the second wing 12a Choose the point of slow down with the button SET or the button 1 of the transmitter for the first wing and with the button RADIO or the button 2 of the remote c...

Page 10: ...by wire the START button or a button in the transmitter 5 The gate begins to open 6 Press the command by wire the START button or the button in the transmitter to set the widening of the pedestrian o...

Page 11: ...is equal to about 0 1 seconds if adjusted to an intermediate position it is equal to about 1 5 seconds while at the maximum the intervention time will be about 3 seconds See also paragraph 11D 8C Tri...

Page 12: ...closing commands neither automatic nor by wire as long as the contact will be opened again The pedestrian opening is a partial opening or total opening if the installer wants it of the wing opened by...

Page 13: ...urrent 11D OBSTACLE DETECTION BY POWER ABSORPTION The control unit has a self test function of the safeties connected to the PHO1 and PHO2 input It switches off the transmitter to check the commutatio...

Page 14: ...gate open warning light The status of the lamp is as follows If the access is closed the light is switched off If the access is open is alight with a fixed light If the access is opening the lamp fla...

Page 15: ...procedure paragraph 5D and reduce at minimum or remove the slowdowns 14F THE AUTOMATION STARTS BUT AT A CERTAIN POINT IT STOPS An external antenna has been connected but the standard cable mounted in...

Page 16: ...King Gates S r l Via A Malignani 42 33077 Sacile PN ITALY Tel 39 0434 737082 Fax 39 0434 785351 e mail info king gates com web www king gates com MADE IN ITALY...

Reviews: