18
EN
02.
Remove the 2 screws underneath the motor and remove the
cover as shown in
Fig. 13
;
Fig. 13
03.
Unscrew the screw in the motor arm and remove it as shown in
Fig. 14
;
Fig. 14
04.
Fix the limit switches on the motor arm
Fig. 15
; these must also
be installed in the presence of mechanical stops on the ground.
Fig. 15
05.
At this point re-install the arm onto the motor
Fig. 16
;
Fig.16
06.
Manually verify that, when opening and closing, the gate leaf
stops at the desired points
Fig. 17
;
Fig.17
07.
By screwing or unscrewing the two screws
(A)
on the motor, the
two limit switches can be adjusted; then, using the two screws
(B)
block the two adjusting screws
(A)
Fig. 18
;
A
A
B
B
Fig. 18
Closing
Closing
Opening
Opening
Closing
Opening