Kinetico PRO CP 213f OD Carbon Owner'S Manual Download Page 8

CP Filter Series Technical Manual

8

System Specifications

Model CP213f OD

Design Specifications

Service Flow Rate - 15 psid (1 bar)

15.0 gpm

57.0 Lpm

Service Flow Rate - 30 psid (2 bar)

20.0 gpm

76.0 Lpm

Pressure Range

25 - 125 psi Dynamic Pressure

1.7 - 8.6 bar Dynamic Pressure

Temperature Range

35˚- 120˚ F

1.7˚- 49˚ C

pH Range

5 - 10 SU

Flow Configuration

Overdrive®

System Components

Media Vessel (Qty. 2)

13" x 54"

330 mm x 1,372 mm

Media Vessel Construction

Wrapped Polyethylene

Empty Bed Volume

3.69 ft

3

104 L

Media Volume

1.50 ft

3

43 L

Under Bedding (each tank)

30/40 Mesh Garnet

Under Bedding Volume (each tank)

0.25 ft

3

 (32.4 lb)

7 L (14.5 kg)

Riser Tube

1" ABS

25.4 mm ABS

Upper Distributor

None

Lower Distributor

0.007” Slots, Engineered Plastic Basket

0.18 mm Slots, Engineered Plastic Basket

Regeneration Control

Non-electric Use Meter

Service

Downflow

Backwash

Upflow

Meter Type - Polypropylene Turbine (Kinetico Full Louver)

0.75 - 40.0 gpm

2.8 - 151.4 Lpm

Connections

Inlet / Outlet Connection

Custom Adapter and E-clip (1 1/2” Sweat Fittings Included)

Drain Connection

0.625” Tube

15.9 mm Tube

Brine Line Connection

0.375” Tube

9.5 mm Tube

Power

None

System Part Number

CP 213f OD, No Media

11289

Optional Accessory: 

 Lockout Kit (For Installation with a Softener)

8070A

Dimensions and Weight

Overall Height

60”

1, 524 mm

Overall Width

27”

686 mm

Overall Depth

13”

330 mm

Shipping Weight

160 lb

72.6 kg

Operating Weight

600 lb

272 kg

Regeneration Specifications

Backwash Volume

130 gal

492 L

Backwash Time

20 min

Backwash Flow Control

6.0 gpm

22.7 Lpm

Disc Selection

Meter Disc

1

2

3

4

5

6

7

8

Usable Gallons between Backwash gal (L):

13,715 

(51,916.9)

6,857 

(25,956.6)

4,751 

(17,984.5)

3,428 

(12,976.4)

2,743 

(10,383.4)

2,285 

(8,649.7)

1,959 

(7,415.6)

1,714 

(6,488.2)

60” (1,5

24 mm)

2.5” (63.5 mm)

27” (686 mm)

13” (330 mm)

Summary of Contents for PRO CP 213f OD Carbon

Page 1: ...Owner s Manual Commercial Plus Filter Series Models CP 213f OD Carbon CP 213f OD Macrolite CP 213f Empty...

Page 2: ...nstallation Getting Started 11 Pre installation Review 11 12 KineticoPRO Filter Installation CP213f 12 13 Troubleshooting Eight steps to determine the problem 14 15 Unfiltered Water 16 Water Running t...

Page 3: ...e equipment specifications section for specific instructions Consult MSDS Sheets A caution icon will be used to present any information that may hold a potential hazard or concern during the installat...

Page 4: ...ed suspended matter and re grade the filter bed When the filter bed loses the capacity for chlorine removal the bed must be replaced If the unit is used in conjunction with a chlorine feed system for...

Page 5: ...equired in parallel to satisfy flow requirement needs Single System Configuration A three valve by pass is recommended for the unit Multi System Configuration A three valve bypass is recommended for e...

Page 6: ...events the media from backwashing out of the tanks Riser Tube A riser tube is used to connect the lower distributor to the control valve The riser tube is 1 0 inch in diameter and it includes a handle...

Page 7: ...which starts regeneration When open the regeneration control valve allows water to pass through a nozzle where it is directed to the regeneration turbine in the regeneration chamber As the regenerati...

Page 8: ...eration Control Non electric Use Meter Service Downflow Backwash Upflow Meter Type Polypropylene Turbine Kinetico Full Louver 0 75 40 0 gpm 2 8 151 4 Lpm Connections Inlet Outlet Connection Custom Ada...

Page 9: ...ed Plastic Basket Regeneration Control Non electric Use Meter Service Downflow Backwash Upflow Meter Type Polypropylene Turbine Kinetico Full Louver 0 75 40 0 gpm 2 8 151 4 Lpm Connections Inlet Outle...

Page 10: ...lots Engineered Plastic Basket Regeneration Control Non electric Use Meter Service Downflow Backwash Upflow Meter Type Polypropylene Turbine Kinetico Full Louver 0 75 40 0 gpm 2 8 151 4 Lpm Connection...

Page 11: ...ilation must be provided when using PVC cleaner or glue A ladder should be used for all work over head that would be beyond your natural reach If working continuously at a height of six feet or more t...

Page 12: ...odes before continuing 3 Install with by pass valve Note the inlet and outlet arrows on valve head 4 Install a pressure gauge and sample tap in the outlet piping 5 Connect the inlet outlet adapters le...

Page 13: ...uctions or kinks Apply Teflon tape to pipe threads on side of filter valve and install the two fittings supplied Connect drain line to valve On drain lines for the CP 213 that must travel more than 8...

Page 14: ...where at the customer site 3 Observe the Installation Look for customer related problems Is the by pass open or leaking Look for obvious installation mistakes Is the meter disc correct according to ra...

Page 15: ...piping 2 Turn on one cold water faucet wide open 3 Place either tank in the backwash portion of cycle Did the pressure drop below 25 psi at the brine fitting The Kinetico valve requires a minimum of...

Page 16: ...currently in service has a problem with its drain valve If the drain water is soft start with number 1 below Problem Reason Solution 1 The balance piston O ring is not seated properly q Water will le...

Page 17: ...during shipping or installation n Re bed the unit 3 Drain flow is less than what is listed in the Specifications Media beds may not be getting backwashed properly q Backwash flow control plugged q Dra...

Page 18: ...re water than he realizes n Obtain a water bill if customer is on a city water system and determine how much water should be used Average water consumption is 75 gallons per day per person 2 The unit...

Page 19: ...isc Part Number 1 1504 2 1505 3 1506 4 1507 5 1508 6 1509 7 1510 8 1511 Level 1 Complete Assemblies Part Number 11252A 23 Complete Assembly Part Number 13665 24 Part numbers can be found on parts page...

Page 20: ...0 2 Cap 1 8697B 8697B 3 Actuator O ring 1 1460 1460 4 Actuator 1 9284A 9284A 5 Seal Cap 1 8628 8628 6 O ring Balance Piston 1 1070 1070 7 Balance Piston 1 14927 14927 8 Spring Balance Piston 1 5448 54...

Page 21: ...4 P2 STEM GEAR P15 PP8 3 2 2 STEM GEAR 2 Description Part Number Gear 1 1522 Gear 2 1523 Gear 3 1524 Gear 4 1525 Gear P2 7886A Gear 14 7894A Gear P15 7895A Gear P16 7896A Gear P20 7898A Gear 5 1526 Ge...

Page 22: ...e standard model number determines the correct column 1 The drawings are representative of Downflow Fast Rinse DFFR units Dwg No Description Qty Req d Model Number 213f OD 1 Level 2 1 8603A 2 Level 3...

Page 23: ...Number 213f OD 1 Level 4 w Retainers 1 11819 2 Main Valve Piston 4 17398 3 Quad Ring 125 Piston 4 1550 4 Control Valve Spring Loaded 1 13720A 5 Quad Ring Drain Control Valve 2 1590 6 Seal Drain Contr...

Page 24: ...elow The standard model number determines the correct column 2 The drawings are representative of Downflow Fast Rinse DFFR units Complete Assembly 6 Dwg No Description Qty Req d Model Number 213f OD 1...

Page 25: ...nits Dwg No Description Qty Req d Model Number 213f OD 1 Seal Main Base 1 8620 2 Main Base Standard 1 8651D 3 O ring Base 1 8925 4 Distributor Tube 2 8322A CAR 11360 Mac 5 Media Tank 2 13417 6 Connect...

Page 26: ...____________________ ____________________________________________________________________________________________________ ______________________________________________________________________________...

Page 27: ...___ ____________________________________________________________________________________________________ _______________________________________________________________________________________________...

Page 28: ...Owner s Manual Commercial Plus Filter Series 2021 Kinetico Incorporated Corporate Headquarters 10845 Kinsman Road Newbury Ohio 44065 www KineticoPRO com Product No 11248D Rev 05 11 2021...

Reviews: