Kinetico PRO CP 213f OD Carbon Owner'S Manual Download Page 3

3

G

eneral

 I

nformatIon

About this Manual

This manual will cover information needed for the proper installation and operation of your KineticoPRO Filtering 

System. We have also included information regarding the frequently asked questions about filtering systems. This 

information may be more technical in nature, but provides further insight to the continued operation of this equipment 

at its highest levels
This manual will use various icons to help highlight issues that are relevant to the safe operation of this equipment. The 

following icons will be used as described:

 

General information

 regarding the application of this product will be highlighted by this icon. This will include 

technical specifications and expected operational results. 

Maintain safe pressure

 

This sign indicates the safe operating pressure range.

Consult Maintenance Section

 

Refer to the maintenance section for specific instructions. 

Consult Equipment Specifications Section

 

Refer to the equipment specifications section for specific instructions.

Consult MSDS Sheets

 A 

caution icon

 will be used to present any information that may hold a potential hazard or concern during the 

installation, use or maintenance of this product. Should this information not be followed, it may result in 

damage to this equipment and its surroundings.

Pinch point or crushing hazard

Chemical hazard

 The 

warning icon

 will be used to present any information that may result in a severe hazard or concern during 

the installation, use or maintenance of this product. Should this information not be followed, it may result in 

severe physical harm.

Stay Clear

Do Not Touch

No Access 

Only properly trained and authorized persons can enter area or open panel.

Any tools or materials required during the installation, use or maintenance of this equipment will be preceded 

by this icon. Using these specific tools will minimize time and effort. Not using the proper tool may result in 

damage to this equipment, its surroundings or even physical harm.

If there are any additional questions pertaining to this equipment, please contact your local KineticoPRO Dealer for 

further assistance.

Summary of Contents for PRO CP 213f OD Carbon

Page 1: ...Owner s Manual Commercial Plus Filter Series Models CP 213f OD Carbon CP 213f OD Macrolite CP 213f Empty...

Page 2: ...nstallation Getting Started 11 Pre installation Review 11 12 KineticoPRO Filter Installation CP213f 12 13 Troubleshooting Eight steps to determine the problem 14 15 Unfiltered Water 16 Water Running t...

Page 3: ...e equipment specifications section for specific instructions Consult MSDS Sheets A caution icon will be used to present any information that may hold a potential hazard or concern during the installat...

Page 4: ...ed suspended matter and re grade the filter bed When the filter bed loses the capacity for chlorine removal the bed must be replaced If the unit is used in conjunction with a chlorine feed system for...

Page 5: ...equired in parallel to satisfy flow requirement needs Single System Configuration A three valve by pass is recommended for the unit Multi System Configuration A three valve bypass is recommended for e...

Page 6: ...events the media from backwashing out of the tanks Riser Tube A riser tube is used to connect the lower distributor to the control valve The riser tube is 1 0 inch in diameter and it includes a handle...

Page 7: ...which starts regeneration When open the regeneration control valve allows water to pass through a nozzle where it is directed to the regeneration turbine in the regeneration chamber As the regenerati...

Page 8: ...eration Control Non electric Use Meter Service Downflow Backwash Upflow Meter Type Polypropylene Turbine Kinetico Full Louver 0 75 40 0 gpm 2 8 151 4 Lpm Connections Inlet Outlet Connection Custom Ada...

Page 9: ...ed Plastic Basket Regeneration Control Non electric Use Meter Service Downflow Backwash Upflow Meter Type Polypropylene Turbine Kinetico Full Louver 0 75 40 0 gpm 2 8 151 4 Lpm Connections Inlet Outle...

Page 10: ...lots Engineered Plastic Basket Regeneration Control Non electric Use Meter Service Downflow Backwash Upflow Meter Type Polypropylene Turbine Kinetico Full Louver 0 75 40 0 gpm 2 8 151 4 Lpm Connection...

Page 11: ...ilation must be provided when using PVC cleaner or glue A ladder should be used for all work over head that would be beyond your natural reach If working continuously at a height of six feet or more t...

Page 12: ...odes before continuing 3 Install with by pass valve Note the inlet and outlet arrows on valve head 4 Install a pressure gauge and sample tap in the outlet piping 5 Connect the inlet outlet adapters le...

Page 13: ...uctions or kinks Apply Teflon tape to pipe threads on side of filter valve and install the two fittings supplied Connect drain line to valve On drain lines for the CP 213 that must travel more than 8...

Page 14: ...where at the customer site 3 Observe the Installation Look for customer related problems Is the by pass open or leaking Look for obvious installation mistakes Is the meter disc correct according to ra...

Page 15: ...piping 2 Turn on one cold water faucet wide open 3 Place either tank in the backwash portion of cycle Did the pressure drop below 25 psi at the brine fitting The Kinetico valve requires a minimum of...

Page 16: ...currently in service has a problem with its drain valve If the drain water is soft start with number 1 below Problem Reason Solution 1 The balance piston O ring is not seated properly q Water will le...

Page 17: ...during shipping or installation n Re bed the unit 3 Drain flow is less than what is listed in the Specifications Media beds may not be getting backwashed properly q Backwash flow control plugged q Dra...

Page 18: ...re water than he realizes n Obtain a water bill if customer is on a city water system and determine how much water should be used Average water consumption is 75 gallons per day per person 2 The unit...

Page 19: ...isc Part Number 1 1504 2 1505 3 1506 4 1507 5 1508 6 1509 7 1510 8 1511 Level 1 Complete Assemblies Part Number 11252A 23 Complete Assembly Part Number 13665 24 Part numbers can be found on parts page...

Page 20: ...0 2 Cap 1 8697B 8697B 3 Actuator O ring 1 1460 1460 4 Actuator 1 9284A 9284A 5 Seal Cap 1 8628 8628 6 O ring Balance Piston 1 1070 1070 7 Balance Piston 1 14927 14927 8 Spring Balance Piston 1 5448 54...

Page 21: ...4 P2 STEM GEAR P15 PP8 3 2 2 STEM GEAR 2 Description Part Number Gear 1 1522 Gear 2 1523 Gear 3 1524 Gear 4 1525 Gear P2 7886A Gear 14 7894A Gear P15 7895A Gear P16 7896A Gear P20 7898A Gear 5 1526 Ge...

Page 22: ...e standard model number determines the correct column 1 The drawings are representative of Downflow Fast Rinse DFFR units Dwg No Description Qty Req d Model Number 213f OD 1 Level 2 1 8603A 2 Level 3...

Page 23: ...Number 213f OD 1 Level 4 w Retainers 1 11819 2 Main Valve Piston 4 17398 3 Quad Ring 125 Piston 4 1550 4 Control Valve Spring Loaded 1 13720A 5 Quad Ring Drain Control Valve 2 1590 6 Seal Drain Contr...

Page 24: ...elow The standard model number determines the correct column 2 The drawings are representative of Downflow Fast Rinse DFFR units Complete Assembly 6 Dwg No Description Qty Req d Model Number 213f OD 1...

Page 25: ...nits Dwg No Description Qty Req d Model Number 213f OD 1 Seal Main Base 1 8620 2 Main Base Standard 1 8651D 3 O ring Base 1 8925 4 Distributor Tube 2 8322A CAR 11360 Mac 5 Media Tank 2 13417 6 Connect...

Page 26: ...____________________ ____________________________________________________________________________________________________ ______________________________________________________________________________...

Page 27: ...___ ____________________________________________________________________________________________________ _______________________________________________________________________________________________...

Page 28: ...Owner s Manual Commercial Plus Filter Series 2021 Kinetico Incorporated Corporate Headquarters 10845 Kinsman Road Newbury Ohio 44065 www KineticoPRO com Product No 11248D Rev 05 11 2021...

Reviews: