background image

R ev. 11/ 20 10  

P age 7

   

P roduc t N o. 14 19 7 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

17

 

18

 

Add Salt 

 
Add a clean grade of salt at this time.   
 
DO NOT USE ROCK SALT OR SOLAR SALT.

 

Purge Air from Plumbing 

 
After the unit is fully pressurized, open a faucet in 
the house to purge air from lines. 
 
Check all other house faucets, and purge air by 
manually cycling unit from one tank to the other. 

Sanitize Softener 
 

Regenerate both tanks. 

 

 

 

 

 

 

 

 

 

 

 
 
 
Use a clean grade of salt appropriate for use with water treatment equipment.  DO NOT USE ROCK SALT OR 
SOLAR SALT. 
 
Mix 29.6 mL of unscented household bleach in 15.1 liters of clean/soft water.  This should make a 100 ppm 
solution.  Use 22.7 liters for commercial units. 
 
Put the system into by-pass. 
 
Disconnect the brine line and put the 3/8” tube into the container holding the bleach mixture from the step above. 
 

Note:

 

Do not add bleach to brine tank. Salts containing red-out additives will create hazardous fumes.

 

 
Put the system into service. 
 
Put the unit into brine draw on one tank. 
 
Draw the mixture until a strong bleach odor is detected (smelled or tested) in the drain line.  This procedure should 
produce approximately 20 ppm in the mixed solution. 
 
Switch quickly to the other tank and repeat the procedure. 
 
Advance the control disc to the service position and allow the unit to stand for 30-60 minutes.  The colder the 
water, the longer the stand time should be. 
 
Put unit into by-pass. 
 
Reconnect the brine line (3/8” tube) to the brine tank and backwash each tank of the softener two times. 
 
Put unit into service. 
 
 
 
 
 
 
 

19

 

 
After regeneration time, 
initiate regeneration on 
second tank.

 

Using #2 Philips screwdriver, 
turn actuator clockwise into 
brine position.

 

Summary of Contents for 2060s

Page 1: ...s OD Check your local building and sanitation codes for installation compliance Installation must meet all state and local codes Check your water quality first This system is not intended to be used f...

Page 2: ...to a torch flame or excessive heat Use only LEAD FREE solder Eye Protection Wear protective eyewear while installing to prevent potential eye injury that could be caused by splattering soldering mater...

Page 3: ...ezing Water conditions Temperature 1 50 C Pressure 1 8 5 Bar 3 5b Connect Adapters for Classic Control Valve Systems Lube O rings Insert adapters Insert adapter bracket Insert adapter pin Connect Adap...

Page 4: ...d inlet water quality see step 10 Connect Softener Connect softener to main plumbing via by pass Do not solder brass adapters while they are inserted in the control module Take care during the install...

Page 5: ...Cup Setting Meter Disc and Brine Valve Chart Select disc based on inlet compensated hardness Meter Disc Number Denotes Compensated Hardness in mg L Model Salt Setting adjuster Float 1 2 3 4 5 6 7 8 20...

Page 6: ...rain line 13 14 Install Brine Tank Overflow Install drain line on the barbed overflow fitting on the drum and connect it to a drain Make sure the drain is not higher than the barbed fitting FOLLOW PLU...

Page 7: ...e 3 8 tube into the container holding the bleach mixture from the step above Note Do not add bleach to brine tank Salts containing red out additives will create hazardous fumes Put the system into ser...

Reviews: