Rev. 11/2010
Page 5
Product No. 14197
Set Brine Valve
Float Cup Setting
(all units)
Remove the brine valve assembly and rest it on a flat surface.
Remove rubber band.
Height is measured from the base of the brine valve assembly to
the top of the float cup (see drawing at right).
Adjuster Tube Setting
(standard and commercial units)
Cut and remove tabs on both sides of
the tube.
Remaining number or letter imprinted on
the tab determines the correct setting.
The drawing at right shows an adjuster
tube at setting "M".
9
Float Cup
Setting
Meter Disc and Brine Valve Chart
Select disc based on inlet compensated hardness.
Meter Disc
Number Denotes Compensated Hardness in mg/L
Model
Salt Setting
(adjuster)
Float
1
2
3
4
5
6
7
8
2020c HF
0.22 Kg
--
--
34
68
86
120
154
188
222
257
0.34 Kg
--
114mm
34
86
120
171
222
257
308
342
2025s 0.45 Kg
1.5 184mm
68 137 205
0.6 Kg
1.5
191mm
86 188 274 359 428
2060s
1.22 Kg
N
153mm
137
257
376
479
581
684
770
855
1.63 Kg
L
185mm
154
308
462
581
701
821
923
1026
1.81 Kg
N
172mm
171
325
479
616
752
872
975
1077
2.00 Kg
N
178mm
188
342
496
650
787
906
1026
1129
2060s OD
1.22 Kg
N
152mm
51
103
154
188
239
291
325
376
1.81 Kg
N 172mm
68
120
188
257
308
359
428
479
2.00 Kg
N
178mm
68
137
205
274
325
393
445
513
10