background image

R ev. 11/ 20 10  

P age 6

   

P roduct N o. 14 19 7

 

 

 

11

 

12

 

Connect Brine Tank 

 
Apply 2 – 3 wraps of Teflon

®

 tape to  nipple on 

control valve.

 

Locate  tube elbow.

 

Hand tighten elbow, then turn once with wrench. 
Attach  tube from elbow to brine valve 

– hand tighten tube side nuts.

 

Make sure tubing is not kinked. 

Install Drain Line 

 
Apply 2 – 3 wraps of Teflon

®

 tape to ½” nipple on 

control valve.

 

Locate ½” x tube elbow. 
Hand tighten elbow, then turn once with wrench. 
Attach  drain line from elbow to drain.

 

Make sure line is not kinked. 
Drain lines must not travel more than 2.4 meters up 

from module head.

 

On lines traveling more than  

10 meters, increase 

 

diameter of the drain line.

 

13

 

14

 

Install Brine Tank Overflow 

 
Install drain line on the barbed overflow fitting on the drum

 

and connect it to a drain.

 

 Make sure the drain is not higher than the barbed fitting.  

 

 FOLLOW PLUMBING CODES.  

 

15

 

16

 

Flush System 

 
Flush both the inlet and outlet lines by opening the 
by-pass valve and allowing water to rinse out any 
debris in the lines. 
 
Flush lines for 10 minutes.

 

Start-Up System 

 
Put by-pass into service position. 

 

Using #2 Philips screwdriver, 
depress and turn actuator 
clockwise into backwash 
position. 

 

Brine tank will begin to fill. 

 

After 5 minutes, turn actuator 
until alternate tank is in 
backwash. 

 
 

 
 

Confirm Drain Air Gap 

 
Waste connections or drain 
outlets shall be designed and 
constructed to provide for 
connection to the sanitary 
waste system through an air 
gap of 2 pipe diameters or  
 25 mm, whichever is larger.

 

 

Summary of Contents for 2060s

Page 1: ...s OD Check your local building and sanitation codes for installation compliance Installation must meet all state and local codes Check your water quality first This system is not intended to be used f...

Page 2: ...to a torch flame or excessive heat Use only LEAD FREE solder Eye Protection Wear protective eyewear while installing to prevent potential eye injury that could be caused by splattering soldering mater...

Page 3: ...ezing Water conditions Temperature 1 50 C Pressure 1 8 5 Bar 3 5b Connect Adapters for Classic Control Valve Systems Lube O rings Insert adapters Insert adapter bracket Insert adapter pin Connect Adap...

Page 4: ...d inlet water quality see step 10 Connect Softener Connect softener to main plumbing via by pass Do not solder brass adapters while they are inserted in the control module Take care during the install...

Page 5: ...Cup Setting Meter Disc and Brine Valve Chart Select disc based on inlet compensated hardness Meter Disc Number Denotes Compensated Hardness in mg L Model Salt Setting adjuster Float 1 2 3 4 5 6 7 8 20...

Page 6: ...rain line 13 14 Install Brine Tank Overflow Install drain line on the barbed overflow fitting on the drum and connect it to a drain Make sure the drain is not higher than the barbed fitting FOLLOW PLU...

Page 7: ...e 3 8 tube into the container holding the bleach mixture from the step above Note Do not add bleach to brine tank Salts containing red out additives will create hazardous fumes Put the system into ser...