Essential Series Gold and Platinum
22
Setting the AccuDial
1. Manually regenerate valve
2. Use disc selection chart to determine
setting
3. Adjust AccuDial by pushing and turn-
ing knob
Document No. 15825
4. Align arrow to setting
5. Make sure knob is up after setting
AccuDial
Manual Regeneration
Using a #2 Phillips screwdriver, push down firmly on the softener valve screw
and slowly turn clockwise, listening for four (4) clicks to start the regeneration.
At this point, you should hear water begin to run through the system. If you do
not hear water running through the system, the disc has not been advanced far
enough.
NOTE:
The hot water tank has refilled with hard water, it may take several days
for it to empty and for the customer’s water to feel soft again.