Technical Manual
21
9a. Add upper meter disc
9b. Add upper disc
10. Add balance piston, spring and O-ring
Hold the meter drive pawl back when in-
serting the upper disc.
Make sure arrow is aligned at 6' o'clock
position
11. Insert return spring into cap
12. Insert actuator and O-ring into cap
13. Add cap O-ring
14. Align superdisc
15. Attach cap to level 1
16a. Bolt valve
6:00
Make sure the AccuDial reset spring aligns
with the upper disc correctly.
Torque the main valve screws to 1.69 Nm
(15 in/lbs) in a crossing pattern.
16b. Bolt valve
8
2
6
3
7
1
5
4