4. The Charging Process:
•  Qualification - Battery Condition Check
 

When the charger is first switched ON it checks the battery condition to determine 
whether the battery needs reconditioning. During this qualification process it checks 
the internal impedance and initial Voltage of the battery and it will determine how much 
charge current, if any that the battery will accept. 

•  Enhanced Battery Rejuvenation - BLUE Bulk LED Flashing Fast 

If the initial qualification detected that the battery was in poor condition, the patented 
rejuvenation process will begin automatically. During the rejuvenation process a high 
Voltage equalising and peak pulse reconditioning charge is used to repair the sulphated 
battery. This unique patented feature will break down and dissolve the lead-sulphate 
crystal build up on the battery plates which will extend the life of your battery.  
It can also balance out high concentrations of acid. The equalisation Voltage will be 
32V DC maximum. If the battery Voltage doesn’t reach 18V DC within 24 hours, the 
Rejuvenation process will time out.

•  Soft Start Charging - BLUE Bulk LED Flashing Slow 

Gently charges the battery using a reduced charge output until the battery Voltages 
reaches 22V DC. If the battery Voltage doesn’t reach 22V DC within 6 hours, the safety 
timer protection will stop the unit from charging and the RED Fault LED and BLUE Bulk 
LED will start flashing.

•  Bulk Charging - BLUE Bulk LED ON

 (Charge Voltage depends on battery type selection)

 

Uses the maximum selected charge output until the battery Voltage reaches 
28.2/28.8/29.4V DC. If the battery Voltage doesn’t reach this within 24 hours, the safety 
timer protection will stop the unit from charging and the RED Fault LED will start 
flashing and the BLUE Bulk LED will be ON.

•  Absorption Charging - GREEN Absorption LED ON  

Uses a constant Voltage while reducing the charging output current to ensure the 
battery receives a full charge without overcharging the battery. 

3. Connect the battery charger to Mains Power (240Vac)
•  The charger will automatically start when AC power is connected and switched ON. 
•  IMPORTANT: Please make sure the correct Battery Type and your desired Charge Rate 

is selected to suit your battery by pressing the Select Buttons within the first 5 minutes 
of charging. For Example do not charge a Gel Battery on the Calcium Battery Type  
setting as this may damage your battery and / or reduce your battery life. 

Note: If the Fault Indicator LED illuminates RED, please check your connections as it’s 
likely that the Positive and Negative Leads are reversed.

KP87007 Ozcharge manual_OC2406U.indd   8

18/04/2018   2:17 PM

Summary of Contents for KP87007

Page 1: ...ON RECONDITIONING TECHNICAL EXPERIENCE N E E D E D NO 100 AUTOMATIC SMART BATTERY CHARGER MAINTAINER ANALYSIS BATTERY CONDITION MICROPROCESSOR CONTROLLED FULLY PATENTED BATTERY REJUVENATION RECONDITIO...

Page 2: ...automatic switched mode 24 Volt battery charger maintainer and rejuvenator Please take the time to carefully read and understand this manual before using this product Table of Contents Know Your Prod...

Page 3: ...or non rechargeable battery Never place the charger on the battery or battery on the charger When working with lead acid batteries remove personal metal items such as rings bracelets necklaces watche...

Page 4: ...tillconnectedinthevehicle Can be left on 24 7 to ensure your battery is always maintained and fully charged The battery charger can be left unattended and left permanently connected all year round The...

Page 5: ...D S FULL GREEN FLASH ON FLASHING IF ANALYSIS FAILED OR ON IF FULLY CHARGED FLOAT MAINTENANCE MODE ABSOR GREEN FLASH ON FLASHING DURING EQUALISATION CHARGING OR ON DURING ABSORPTION CHARGING BULK BLUE...

Page 6: ...N The charger will automatically turn OFF if the output leads are short circuited and the fault LED will come ON This prevents the charger from being damaged if the positive and negative crocodile cli...

Page 7: ...attery charger to your battery SEE QR CODE FOR QUICK START PRODUCT VIDEO Fig 1 Fig 2 Fig 3 ELECTRICAL PARTS ACCESSORIES AC Power Cord 1 8m with SAA 3 Pin AU Plug DC Output Lead 1 2m with quick connect...

Page 8: ...attery Voltages reaches 22V DC If the battery Voltage doesn t reach 22V DC within 6 hours the safety timer protection will stop the unit from charging and the RED Fault LED and BLUE Bulk LED will star...

Page 9: ...ON This stage allows you to keep the charger connected 24 7 to ensure your battery is well maintained and kept 100 fully charged Float mode will maintain the battery at a constant 27 2V DC Long Term M...

Page 10: ...10 SMART 9 STAGE BATTERY CHARGER MAINTAINER 24V 6 AMP CHARGING CURVE KP87007 Ozcharge manual_OC2406U indd 10 18 04 2018 2 17 PM...

Page 11: ...is only present when connected to a battery NO charging current Fault RED LED is Flashing Battery is severely sulphated Battery has a damaged cell Over temperature protection mode Check the battery c...

Page 12: ...are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the go...

Reviews: