kincrome KP87007 Manual Download Page 1

SMART 9-STAGE BATTERY 

CHARGER & MAINTAINER

24V 6 AMP

KP87007

ED1/Feb 18

100%

AUTOMATIC

SMART BATTERY

CHARGER &

MAINTAINER

ANALYSIS

BATTERY

CONDITION

MICROPROCESSOR

CONTROLLED

FULLY

PATENTED

BATTERY

REJUVENATION

(RECONDITIONING)

TECHNICAL

EXPERIENCE 

N E E D E D

NO

100%

AUTOMATIC

SMART BATTERY

CHARGER &

MAINTAINER

ANALYSIS

BATTERY

CONDITION

MICROPROCESSOR

CONTROLLED

FULLY

PATENTED

BATTERY

REJUVENATION

(RECONDITIONING)

TECHNICAL

EXPERIENCE 

N E E D E D

NO

100%

AUTOMATIC

SMART BATTERY

CHARGER &

MAINTAINER

ANALYSIS

BATTERY

CONDITION

MICROPROCESSOR

CONTROLLED

FULLY

PATENTED

BATTERY

REJUVENATION

(RECONDITIONING)

TECHNICAL

EXPERIENCE 

N E E D E D

NO

KP87007 Ozcharge manual_OC2406U.indd   1

18/04/2018   2:17 PM

Summary of Contents for KP87007

Page 1: ...ON RECONDITIONING TECHNICAL EXPERIENCE N E E D E D NO 100 AUTOMATIC SMART BATTERY CHARGER MAINTAINER ANALYSIS BATTERY CONDITION MICROPROCESSOR CONTROLLED FULLY PATENTED BATTERY REJUVENATION RECONDITIO...

Page 2: ...automatic switched mode 24 Volt battery charger maintainer and rejuvenator Please take the time to carefully read and understand this manual before using this product Table of Contents Know Your Prod...

Page 3: ...or non rechargeable battery Never place the charger on the battery or battery on the charger When working with lead acid batteries remove personal metal items such as rings bracelets necklaces watche...

Page 4: ...tillconnectedinthevehicle Can be left on 24 7 to ensure your battery is always maintained and fully charged The battery charger can be left unattended and left permanently connected all year round The...

Page 5: ...D S FULL GREEN FLASH ON FLASHING IF ANALYSIS FAILED OR ON IF FULLY CHARGED FLOAT MAINTENANCE MODE ABSOR GREEN FLASH ON FLASHING DURING EQUALISATION CHARGING OR ON DURING ABSORPTION CHARGING BULK BLUE...

Page 6: ...N The charger will automatically turn OFF if the output leads are short circuited and the fault LED will come ON This prevents the charger from being damaged if the positive and negative crocodile cli...

Page 7: ...attery charger to your battery SEE QR CODE FOR QUICK START PRODUCT VIDEO Fig 1 Fig 2 Fig 3 ELECTRICAL PARTS ACCESSORIES AC Power Cord 1 8m with SAA 3 Pin AU Plug DC Output Lead 1 2m with quick connect...

Page 8: ...attery Voltages reaches 22V DC If the battery Voltage doesn t reach 22V DC within 6 hours the safety timer protection will stop the unit from charging and the RED Fault LED and BLUE Bulk LED will star...

Page 9: ...ON This stage allows you to keep the charger connected 24 7 to ensure your battery is well maintained and kept 100 fully charged Float mode will maintain the battery at a constant 27 2V DC Long Term M...

Page 10: ...10 SMART 9 STAGE BATTERY CHARGER MAINTAINER 24V 6 AMP CHARGING CURVE KP87007 Ozcharge manual_OC2406U indd 10 18 04 2018 2 17 PM...

Page 11: ...is only present when connected to a battery NO charging current Fault RED LED is Flashing Battery is severely sulphated Battery has a damaged cell Over temperature protection mode Check the battery c...

Page 12: ...are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the go...

Reviews: