10T HYDRAULIC BODY REPAIR KIT
Office Contact Details:
Phone:
1300 657 528
Fax:
1300 556 005
Email:
Website:
www.kincrome.com.au
YEAR
WARRANTY
2
Warranty given by Kincrome Australia Pty Ltd of 3 Lakeview Drive, Caribbean Park, Scoresby, Victoria (Tel 1300 657 528). The applicable warranty period
(2 years) commences on the date that the product is purchased. If this product has materials or workmanship defects (other than defects caused by abnormal
or non warranted use) you can, at your cost, send the product to place of purchase, an authorised Kincrome service agent or one of Kincromes addresses for
repair or replacement. Your rights under this warranty are in addition to any other rights you have under the Australian Consumer Law or other applicable laws.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure
and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of
acceptable quality and the failure does not amount to a major failure. For further details please visit www.kincrome.com.au or call us. Due to minor changes in
design or manufacture, the product you purchase may sometimes differ from the one shown on the packaging.
Distributed by Kincrome Tools and Equipment www.kincrome.com.au 3 Lakeview Drive Scoresby Victoria Phone: 1300 657 528
WARRANTY
TROUBLESHOOTING
Symptom
Cause
Remedy
Pump unit will not work
1. Release valve (9) is open.
2. Dirt on valve seats.
3. Worn seals.
1. Close the release valve (9).
2. Clean valve seats.
3. Replace seals.
Pump unit will not produce
pressure
1. The reservoir could be overfilled or low on
hydraulic fluid .
2. Leak in the hose, seals, or connections
3. Air trapped in the system.
1. Check the fluid level. Do not
overfill.
2. Check the hose and replace if
necessary. Make sure all connections
are tight.
3. Open the release valve (9).
Pump the handle a couple of full strokes.
Close the release valve (9).
4. Contact Kincrome Customer Service
Pump unit will not lower
completely
1. Air trapped in the system.
2. The reservoir could be overfilled or low on
hydraulic fluid.
1. Open the release valve (9) .
Pump the handle a couple of full strokes.
Close the release.
2. Check the fluid level is correct. Do not
overfill.
Ram will not fully extend
Low on hydraulic fluid.
1. Check that oil level is correct.
2. Check oil with ram fully retracted.
3. Add hydraulic fluid.
Fluid leaking from release
valve
Worn O-ring.
Replace O-ring.
Fluid leaking from hose
Damaged hose.
Replace hose.
Fluid leaking around
hydraulic ram piston
Worn seal or piston.
Please contact Kincrome customer
service.