18 Options
In complement of the five measurement modes in the device,
DB300
proposes optional modes and processing software which enlarge
the user investigation domain.
F-13: Analyzer – integrating averaging with storage sound level meter function – filters by third octave bands from 12,5 Hz to
20 kHz (class 1) or from 25 Hz to 10 kHz (class 2)
The spectral analysis by filters of
third octave
bands enables a specific description of sound ambiance in industry, building and
environment, in matter of marked tonalities.
The operating principle of this mode is the same as the one integrating the filters by octave bands. For any use which is not detailed
below, please see the following mode:
Analyzer – integrating averaging with storage sound level meter function – filters by
octave bands from 16 Hz to 16 kHz (class 1) or from 31.5 Hz to 8 kHz (class 2).
During operation: synoptic
➢
Press the On/Off button until the display of the start screen.
➢
Press OK after a time delay of a few seconds.
➢
Move the cursor on the corresponding icon to the filters by third octave bands analyzer mode which becomes video
reversed, then
OK
on this area.
➢
Press Esc to go back to the general screen.
Options
69
DB300
E1
130
110
090
080
070
050
030
010
A C Z 16 63 250 1k 4k 16K
65.4
.
125
dB
1/8s 15:37:28
Hz
Man
01s
RAZ
Analyzer with storage and filters
by third octave bands