7.2.4
Stop the measurement
➢
Stop the measurement pressing .
➢
Press
OK
.
Note
: When
STOP?
is displayed, it is possible to press key to back to measurement screens and keep going.
Note
: It is not possible to stop the measurement as long as the first logging time (ex: DI=60) is not completed. Pressing key will
be inoperative.
7.2.5
Store data
At the end of the measurement, in manual made, a screen of all results is displayed. It is then possible to:
➢
Accept measurements and store them: move the cursor on
Sto.
and press once on
OK
key to confirm. A banner displays the
storage phase.
➢
Reject measurements and not store them: move the cursor on
RST
and press
twice
on
OK
key to confirm. A banner displays
the phase of suppression of data.
Timer and I/O modes:
data storage is automatically made without intervention
7.3 Analyzer integrating - averaging with storage sound level meter function
➢
Select
mode 1/1 oct
mode: move the cursor with the arrows to then press
OK
.
The sound level meter runs as a frequency analyzer and processes the acoustic signal according to the temporal mode:
On a T(D) measurement duration with data storage for each DI elementary integration time
Measured and stored data for each integration time:
•
LAeq, DI:
equivalent continuous level of sound pressure on the elementary integration time.
•
LCeq, DI:
equivalent continuous level of sound pressure on the elementary integration time.
•
LXeq, DI
: equivalent continuous level of sound pressure on the elementary integration time filtered by octave bands from
16 Hz to 16 kHz (class 1) or from 31.5 Hz to 8 kHz (class 2).
•
LUpk:
level of maximum peak of sound pressure on the elementary integration time.
•
Measurement duration
in
DD/HH:MM:SS
Perform some measurements
29
Ongoing measurement
Results screen
Storage
.
LpkC
LAeqmax
LAeqmin
LAeq
LAE
T
L01
L10
L50
L90
L95
99,5 dB
98,7 dB
31,4 dB
67,4 dB
78.5 dB
00:01:30
02%
95,4 dB
75,9 dB
68,1 dB
45,6 dB
33,2 dB
Sto.
Raz
89,1
LpK
C
dB
01s
.
88.7
91.4
86.7
90.8
dB
dB
E1
dB
dB
T = 00/00:00:28
LAeq
LCeq
LAeq,T
LCeq,T
Leq-St.
.
STOP
S11 ?
Leq-St.
.
STO. S11
.
LpkC
LAeqmax
LAeqmin
LAeq
LAE
T
L01
L10
L50
L90
L95
99,5 dB
98,7 dB
31,4 dB
67,4 dB
78.5 dB
00:01:30
02%
95,4 dB
75,9 dB
68,1 dB
45,6 dB
33,2 dB
Sto.
Raz
Results screen
RST active
Deletion
.
LpkC
LAeqmax
LAeqmin
LAeq
LAE
T
L01
L10
L50
L90
L95
99,5 dB
98,7 dB
31,4 dB
67,4 dB
78.5 dB
00:01:30
02%
95,4 dB
75,9 dB
68,1 dB
45,6 dB
33,2 dB
Sto.
Raz
.
LpkC
LAeqmax
LAeqmin
LAeq
LAE
T
L01
L10
L50
L90
L95
99,5 dB
98,7 dB
31,4 dB
67,4 dB
78.5 dB
00:01:30
02%
95,4 dB
75,9 dB
68,1 dB
45,6 dB
33,2 dB
Sto.
Raz
Leq-St.
.
RAZ
S11 ?
Leq-St.
.
RAZ
S11
Leq-St.
.
RAZ
S11 ?