9. Functions recap and Modbus connections
9.1.
F 100 : Configure the transmitter
Code
Register type
Modbus
Description
Possibilities
F 100
Real
1000
Transmitter serial number
F 101
-
1010
Firmware version
-
U32
1020
Device identification
-
U32
1030
Probe identification
F 140
Boolean
1400
Keypad lock
0 : deactivated
1 : activated
F 141
U16
1410
Security code
F 150
U8
1500
Modbus slave number
From 1 to 255
F 151
Enumeration*
1510
Modbus speed
communication
2400 / 4800 / 9600/ 19200 / 38400
/ 115200 bds
F 171
U32
-
Modbus option
-
F 173
-
-
Ethernet option
-
F 180
Boolean
1800
Digital input
On / Off
F 190
Boolean
1900
Restore factory
configuration
9.2.
F 200 : Configure the channels and the measurement units
Code
Register type
Modbus
Description
Possibilities
F 200
Enumeration*
2010
Channel 1 activation
On / Off
F 201
Enumeration*
2000
Channel 1 unit selection
According to the channel to
display
F 210
Enumeration*
2110
Channel 2 activation
On / Off
F 211
Enumeration*
2100
Channel 2 unit selection
According to the channel to
display
F 220
Enumeration*
2210
Channel 3 activation
On / Off
F 221
Enumeration*
2200
Channel 3 unit selection
According to the channel to
display
See Enumeration table page 8
Functions recap and Modbus connections
20