![Kimball Fluent Series Assembly Instructions Manual Download Page 21](http://html1.mh-extra.com/html/kimball/fluent-series/fluent-series_assembly-instructions-manual_1967238021.webp)
Fluent
®
2
Proper product installation, in accordance with these instructions, is the responsibility of the installing agent.
If you have any questions concerning these instructions, please call Kimball Office Customer Care.
Part # 2205363, Revision B
Assembly Instructions
5.
Drill the appropriate diameter hole in the hanger rail per
the fastener manufacturer’s guidelines, 3/8” above the bot-
tom edge of the rail at the locations marked in Step 4.
(Figure C).
Note:
Holes sizes are dependent on the size of the fastener
selected.
6.
Attach hanger rail to wall aligning bottom edge of rail with
level line drawn in Step 1. Ensure that each fastener is
securely attached to wall substructure. (Figure D).
7.
Place overhead cabinet flush against the wall so that the
hanger brackets attached to the overhead are above the
wall hanger rail and is between the end panels of the over-
head. Carefully lower the overhead cabinet until the cabi-
net hanger brackets engage the wall hanger rail. Make sure
the cabinet hanger brackets are firmly seated on the wall
hanger rail. (Figure E).
Installation (continued)
Figure C
Figure D
Hanger Bracket
Centerline of
stud
Recommended Fastener
Size
Model No.
Steel Stud (for 1/2” to 3/4”
drywall):
Hilti Toggle anchor toggle
bolt
1/4”-20 x 2”
Grade 5 or
equivalent with
maximum head
height of .134”
374494
Wood stud (for 1/4” to 1/2”
drywall; meets of exceeds
ANSI/ASME B18.6.4 and SAE
J933)
Panhead sheet metal screw
10-2 PHPMS
Solid Masonry:
Crown Bolt lag shields
Buildex Tapcon concrete
anchor screw
1/4” x 1 1/2”
1/4” x 2 3/4”
Masonry Block:
Hilti Toggle anchor toggle
bolt
Crown Bolt Lag shields
Buildex Tapcon concrete
anchor screw
1/4”-20 x 2”
Grade 5 or
equivalent with
maximum head
height of .134”
1/4” x 1 1/2”
1/4” x 2 3/4”
374494
Boer through this
side
Figure E
3/8”
Fastener (not
supplied)
Centerline of
stud/fastener
Level line
from Step 1
Cut rail 2” shorter
than overhead
72 & 90” double
height overheads
only.
Hanger Rail
Overhead