6.4. Resetting the HAB™
If necessary, you can reset the HAB™ by first turning it on using the front power button, and then
pressing and holding down the power button for 10 seconds. This will clear any alarms and protec-
tion locks. This will not reset the cycle count.
Kilovault recommends recalibration every 6 months & more frequently if they’re not being cycled.
This manual
is f
or
use b
y qualified personnel
onl
y
6.5. Initial HAB™ Unboxed Voltage
If your HAB™ has a low initial voltage when unboxed, refer to the following information.
If, when you turn on your KiloVault® HAB™ , you measure a very low voltage (under 40 V) at the
battery terminals, it is in Low Voltage Hibernation. Press the front power button for three seconds
to turn the KiloVault® HAB™ off. Wait five seconds. Press and hold the power button for 10 sec-
onds. Wait five seconds. Press and hold the front power button to start the KiloVault® HAB™ .
Rev: 5.0
44
HAB Inst/UserManual REV5.0.indd 44
HAB Inst/UserManual REV5.0.indd 44
10/10/22 3:46 PM
10/10/22 3:46 PM