3
9
10. External Input Control Function Description
Connector No.
Definition
Function Description
CN 1
External start signal input
START_IN
1. The screwdriver starts when the CN1+CN2 is at short-circuit
(CLOSE)
2. The screwdriver stops when CN1+CN2 is at open-circuit (OPEN)
CN 2
GND
CN 3
External Reverse Signal
Input REVERSE
1. The external reversal signal CN3+CN4 is short-circuited first
(CLOSE). When the activation signal CN1+CN2 is short-circuited
(CLOSE), the screwdriver starts reverse rotation.
2. The external reversal signal CN3+CN4 is open-circuited first
(OPEN). When the signal CN1+CN2 is short-circuited (CLOSE),
the screwdriver starts forward rotation.
CN 4
GND
CN 5
Disable externally signal
input DISABLE
1. Screwdriver cannot start when CN5+CN6 is short-circuited
(CLOSE)
2. The screwdriver can start when CN5+CN6 is open-circuited
(OPEN)
CN 6
GND
CN 7
External confirmation
button enter CONFIRM
1. When the system requires confirmation, it can be replaced by this
CN7+CN8 short circuit (CLOSE)
2. NG signal will be cleared after CONFIRM is run
CN 8
GND
CN 9
External confirmation
button enter CLEARED When the counter value is to be cleared, the function can be enabled
by this CN9+CN10 short-circuit (CLOSE).
CN 10
GND
CN 11
External sensor switch
GATE
1. Enter a confirmation signal for the machine to determine the
locked object as a valid value
2. Inductive switch: external switch in operation, connect one or two
switches
3. For any switch connection, CN14 must be connected
CN 12
GND
CN 13
External confirmation
button enter RESET JOB When the Job is to be reseted, the function can be enabled by this
CN13+CN14 short-circuit (CLOSE).
CN 14
GND