Insert the other end of the 14-core flat cable into the SYNC OUT connector of
the EX01-PFX installed in the option slot of the PFX2532.
Use the lock lever to secure it. Check that it does not fall out.
Connecting to a PC
To increase the number of voltage measurement points by inserting an OP03-PFX into the SL01-
PFX, you need to use the LAN interface.
You do not need to change the S1 switch on the rear panel from the factory default setting.
IP address is automatically assigned regardless of whether auto IP address assignment (connect via
a router) is used or a fixed IP address (connect via a switching hub) is used.
■
Necessary cable and device
•
LAN cable
•
Switching hub or router
Signal
name
Logic
Notes
Factory
default
5
TEST: Always set to 0.
For
maintenan
ce
0
4
RESV: Always set to 0.
Not used
0
3
0
2
0
1
IP: Always set to 1.
—
1
Factory default
switch position
SL01-PFX