background image

25

fCC

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This 

device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation.

Summary of Contents for TRUSENSE SMOKE 3050-VAS10

Page 1: ...t Model 3050 VAS10 120V HARDWIRE INTERCONNECT 10 year battery backup VOICE ALARM SMOKE ALARM P N 1328 7201 00 Rev A 10 YEAR SMOKE ALARM P U S H B U T T O N TO TEST WEEKLY O R T O H U S H A d v a n c e...

Page 2: ...It is not designed for use in a recreational vehicle RV or boat Note Please thoroughly read this user guide and save the document for future reference and to pass on to any subsequent owner The Natio...

Page 3: ...roduction Product Features And Specifications 8 6 Limitations Of Smoke Alarms 9 7 Recommended Locations For Smoke Alarms 10 8 Locations To Avoid 13 9 Wiring Installation Activation 14 10 Operation And...

Page 4: ...ny inside door without first feeling its surface If hot or if you see smoke seeping through cracks don t open that door Instead use your alternate exit If the inside of the door is cool place your sho...

Page 5: ...for Alert small children in the home as well as anyone else that might have difficulty recognizing the impor tance of the alarm sounding or that might have difficulty leaving the area without help Do...

Page 6: ...ed a smoke alarm event Red LED blink every 16 sec After button push voice Smoke previously detected NOTE On DC power alarm memory is only retained for 24 hrs Push button to clear Alarm Memory Smoke Al...

Page 7: ...c Chirp every 30 sec voice Smoke Sensor Error every 60 sec After 1 hour on DC power voice occurs only after button is pushed See Cleaning Your Alarm section Push button once to attempt to reset the un...

Page 8: ...prior to installing the unit NOTE AC power must be connected to obtain the full 10 year battery and unit life Product Features and Specifications Temperature Operating Range 40 F 4 4 C to 100 F 37 8...

Page 9: ...e For these people additional strategies such as protection in place or assist ed escape or rescue are necessary For maximum detection of the various types of fires that can occur within the home incl...

Page 10: ...closed The closed door may prevent an alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on...

Page 11: ...permitted for smoke alarms and smoke detectors on tray shaped ceilings NFPA 72 states Smoke alarms in rooms with ceiling slopes greater than 1 ft in 8 ft 3m in 2 4 m horizontally shall be located on...

Page 12: ...mes have been designed and built to be energy efficient Install smoke alarms as recommended above In older mobile homes that are not well insulated compared to present standards extreme heat or cold c...

Page 13: ...F or rise above 100 F such as garages and unfinished attics In dusty areas Dust particles may cause nuisance alarms or a failure to alarm In very humid areas above 95 RH non condensing as moisture or...

Page 14: ...Electrical Code ANSI NFPA 70 NFPA 72 and or any other codes having jurisdiction in your area The multiple station interconnect wiring to the alarms must be run in the same raceway or cable as the AC...

Page 15: ...ot be operated from power derived from a square wave modified square wave or modified sine wave inverter These types of inverters are sometimes used to supply power to the structure in off grid in sta...

Page 16: ...remote signaling devices and or relay modules see below for details on interconnecting Kidde devices Figure 9 C illustrates interconnection wiring Improper connection will result in damage to the alar...

Page 17: ...te the battery to eliminate the false low battery trouble condition chirps and voice Attach unit to mounting bracket very soon after applying AC power to avoid false low battery notification NOTE The...

Page 18: ...lectronic circuitry horn speaker and battery are working If the alarm or voice does not sound or gives erratic or low volume sound the unit must be replaced See Perma nently Disable Alarm Discharge Ba...

Page 19: ...nuisance alarms Cigarette smoke will not normally cause the unit to alarm unless the smoke is blown directly into the alarm Combustion particles from cooking may set off the alarm if it is located to...

Page 20: ...THE ALARM FOR ANY REASON Do not try to repair the alarm yourself Low Battery This alarm is equipped with a low battery monitor circuit If the battery capacity is nearing the point where it can no lon...

Page 21: ...e for disposal by draining the battery Figures 13 A top and 13 B bottom 13 Permanently Disable Alarm Discharge Battery WARNING Failure to DISCHARGE alarm battery as instructed prior to disposal may cr...

Page 22: ...could damage the alarm If the alarm is in Fault mode the alarm may be in need of cleaning After cleaning press the button If the fault does not clear the alarm needs to be replaced Never use detergent...

Page 23: ...to test your plan before an emergency You may not be able to reach your children It is important they know what to do Familiarize everyone with the sounds of the smoke alarm and train them to leave y...

Page 24: ...can result in improper operation California State Fire Marshal Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as...

Page 25: ...15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interferenc...

Page 26: ...ity and fitness for a particular purpose are limited in duration to the above warranty period In no event shall the Manu facturer be liable for loss of use of this product or for any indirect special...

Page 27: ...27 QUESTIONS OR FOR MORE INFORMATION Call Kidde Product Support line at 1 800 880 6788 or contact us at www kidde com Kidde 1016 Corporate Park Drive Mebane NC 27302 Made in China...

Reviews: