6. Limitations of Smoke Alarms

 wArnIng:  pleASe reAd cArefUlly And tHOrOUgHly

product features and Specifications:

  

Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to 

escape, followed by the appropriate egress actions by those occupants.

  

Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal 

fires. Victims are often intimate with the fire, too old or young, or physically or mentally impaired such that they 

cannot escape even when warned early enough that escape should be possible. For these people, other strategies 

such as protection-in-place or assisted escape or rescue are necessary.

  

Leading authorities recommend that both ionization and photoelectric smoke alarms be installed to help insure 

maximum detection of the various types of fires that can occur within the home. Ionization sensing alarms may 

detect invisible fire particles (associated with fast flaming fires) sooner than photoelectric alarms. Photoelectric 

sensing alarms may detect visible fire particles (associated with slow smoldering fires) sooner than ionization alarms.

  

A battery powered alarm must have a battery of the specified type, in good condition and installed properly (This 

model has a sealed backup battery).

  

Smoke alarms must be tested regularly to make sure the battery and the alarm circuits are in good operating condition.

  

Smoke alarms cannot provide an alarm if smoke does not reach the alarm. Therefore, smoke alarms may not sense 

fires starting in chimneys, walls, on roofs, on the other side of a closed door or on a different floor.

  

If the alarm is located outside the bedroom or on a different floor, it may not wake up a sound sleeper.

  

The use of alcohol or drugs may also impair one’s ability to hear the smoke alarm. For maximum protection, a smoke 

alarm should be installed in each sleeping area on every level of a home.

This alarm is not intended to alert hearing impaired individuals.

Summary of Contents for P4010ACS

Page 1: ...onnect Model P4010ACS 120V Hardwire 10 year battery backup VOICE ALARM Ambient light sensor SMOKE ALARM Ambient light sensor Alarm samples the ambient light conditions of its location and if possible...

Page 2: ...t It is not designed for use in a recreational vehicle RV or boat Note Please thoroughly read this user guide and save the document for future reference and to pass on to any subsequent owner The Nati...

Page 3: ...ntroduction Product Features Specifications 8 6 Limitations of Smoke Alarms 9 7 Recommended Locations For Smoke Alarms 10 8 Locations To Avoid 10 9 Wiring Installation Activation 12 10 Operation And T...

Page 4: ...it If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in If the escape route requires you to go through smoke stay cl...

Page 5: ...accounted for Alert small children in the home as well as anyone else that might have difficulty recognizing the impor tance of the alarm sounding or that might have difficulty leaving the area withou...

Page 6: ...the last hour Red and Amber LED alternate on 1 sec every 10 sec After button push Smoke previously detected only on the initiating alarm unit Push test button to clear Alarm Memory NOTE stan dard test...

Page 7: ...ife Double chirp every 30 sec First 5 mins Voice every 30 sec Replace alarm press button to temporarily silence Voice stops after 5 mins After 7 days Chirps continue Voice every 30 sec for 5 mins Repl...

Page 8: ...nstalling the unit NOTE AC power must be connected to obtain the full 10 year battery and unit life Product Features and Specifications Temperature Operating Range 40 F 4 4 C to 100 F 37 8 C Humidity...

Page 9: ...home Ionization sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles as...

Page 10: ...the room Ceiling mounting is preferred in ordinary residential construction ANYWHERE ALONG THIS BOLD SURFACE Locations permitted for smoke alarms and smoke detectors on tray shaped ceilings ANYWHERE A...

Page 11: ...269 Mobile Home Installation Modern mobile homes have been designed and built to be energy efficient Install smoke alarms as recommended above In older mobile homes that are not well insulated compare...

Page 12: ...ducts used for heating or cooling ceiling or whole house ventilating fans or other high air flow areas Near lights Electronic noise generated by the electronics may cause nuisance alarms Do not insta...

Page 13: ...Leave the red wire insu lating cap in place to make certain that the red wire cannot contact any metal parts or the electrical box When alarms are hardwire interconnected all interconnected units must...

Page 14: ...onnector snap into place Then push the excess wire back into the electrical box through the hole in the center of the mounting bracket Install the alarm fully on the mounting bracket by rotating the a...

Page 15: ...When one hardwired interconnect unit sounds an alarm all other compatible hardwired interconnected units will also alarm The following models can be interconnected using the standard AC wiring interc...

Page 16: ...battery are working If the alarm or voice does not sound or gives erratic or low volume sound the unit must be replaced See Permanently Disable Alarm Discharge Battery section to determine how to prep...

Page 17: ...the Hush period the smoke alarm will automatically reset and sound the alarm if particles of combustion are still present You can use Hush repeatedly until the air has been cleared of the condition ca...

Page 18: ...r but also contains a sealed lithium battery backup system No battery installation or replacement is necessary for the life of the alarm NOTE AC power must be connected to obtain the full 10 year batt...

Page 19: ...function Once the alarm battery has been discharged the alarm cannot be mounted onto the mounting plate or reactivated To Permanently Disable Alarm Discharge Battery Rotate the alarm counterclockwise...

Page 20: ...de and the Red LED is blinking a fault code of 10 or 14 flashes after a Test Hush button push the alarm may be in need of cleaning After cleaning press the Test Hush button If the fault does not clear...

Page 21: ...o test your plan before an emergency You may not be able to reach your children It is important they know what to do Familiarize everyone with the sounds of the smoke alarm and train them to leave you...

Page 22: ...at can result in improper operation California State Fire Marshal Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household...

Page 23: ...with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including i...

Page 24: ...facturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product wheth...

Reviews: