PHOTOELECTRIC SMOKE AND FIRE ALARM 
USER’S GUIDE

MODEL PE120

A.C. Wire-in Single and/or Multiple Station (24 units maximum)
Photoelectric Smoke Alarm with 9 Volt Battery Back Up

Thank you for purchasing this Fyrnetics smoke and fire alarm.  It is an
important part of your family’s home safety plan.  You can trust
Fyrnetics to provide the highest quality safety products.  We know you
expect nothing less when the lives of your family are at stake.

For your convenience, write down the following information.

If you call our Consumer Hotline, these are the first questions

you will be asked.

Smoke Alarm Model Number (located on back of detector):

Date Code (located on back of detector).  Manufacturer recommends
replacing this alarm ten years from the date code:

Date of Purchase:

Where Purchased:

LISTED

Summary of Contents for PE120

Page 1: ...an You can trust Fyrnetics to provide the highest quality safety products We know you expect nothing less when the lives of your family are at stake For your convenience write down the following information If you call our Consumer Hotline these are the first questions you will be asked Smoke Alarm Model Number located on back of detector Date Code located on back of detector Manufacturer recommen...

Page 2: ...tallation select locations carefully to avoid thermal barriers that may form at the ceiling For more details see MOBILE HOME INSTALLATION below When mounting an alarm on the ceiling locate it at a minimum of 4 10 cm from the side wall and 2 feet 60 96 cm from any inside corner see Diagram A When mounting the alarm on the wall it is best to use an inside wall with the top edge of the alarm at a min...

Page 3: ...will result in damage to the alarm failure to operate or a shock hazard Make certain alarms are wired to a continuous non switched power line NOTE Use standard UL listed household wire 18 gauge or larger as required by local codes available at all electri cal supply stores and most hardware stores FIGURE 1 INTERCONNECT WIRING DIAGRAM WIRES ON DETECTOR HARNESS CONNECTED TO Black Hot Side of A C Lin...

Page 4: ...e alarm senses products of combustion and goes into alarm the red LED will flash rapidly 2 3 times per second The rapid flashing LED and pulsating alarm will continue until the air is cleared Low Battery Condition The LED flash will be accompanied by an audible chirp Replace the battery when this condition occurs SMOKE SENSING CHAMBER OPERATION This alarm will chirp if any of the components in the...

Page 5: ...alarms offer a broad range of fire sensing capabilities but are better at detecting fast flaming fires than slow smoldering fires Photoelectric alarms sense smoldering fires better than flaming fires Home fires develop in dif ferent ways and are often unpredictable Neither type of alarm photoelectric or ionization is always best and a given alarm may not always provide warning of a fire A battery ...

Page 6: ...unit Return it for servicing to Fyrnetics 1394 South Third St Mebane N C 27302 See Warranty for in warranty returns FIVE YEAR LIMITED WARRANTY Fyrnetics warrants to the original purchaser that the enclosed smoke alarm but not the bat tery will be free from defects in material and workmanship or design under normal use and service for a period of five years from the date of purchase The obligation ...