background image

(For Models KF1R and KF2R only):

NOTE:

Rechargeable lithium batteries are permanently mounted and
sealed in the tamper-proof housing. These cells are designed to
last the useful life of the smoke alarm.

1. Turn off power to smoke alarm at main consumer panel.
2. Insert a small screwdriver into the slot in the mounting plate. Depress

locking tab with the screwdriver and turn smoke alarm counter-clock-
wise to detach from mounting plate.

3. Gently pull down smoke alarm. Be careful not to separate cable 

connections.

4. Pull out power plug from back of smoke alarm.

5. From back of smoke alarm, lift tab to open battery pocket door.

6. Remove battery from pocket. Disconnect and discard drained battery

from battery connector.

7. Connect a fresh, 9-volt battery to connector. The battery will fit only

one way. Be sure battery connector is securely attached to battery 
terminals. Smoke alarm may sound a short beep when battery is
installed. This is normal and means the battery is installed correctly.

8. Place battery into battery pocket.

9.

Close battery pocket door. 

Push down until it snaps into place.

10. Press and hold test button. The alarm will sound if the battery is 

properly connected and working.

11. Replace connector plug. Connector will snap into place. Gently tug

connector to be sure it is attached properly.

12. Reattach smoke alarm to mounting plate by turning smoke alarm

clockwise until it snaps into place.

13. Turn on power and test smoke alarm using test button.

CLEANING 

Clean the smoke alarm at least once a month

to remove dust, dirt, or

debris. Always turn off power to smoke alarm before cleaning.

Using the soft brush or wand attachment to a vacuum cleaner, vacuum all
sides and cover of smoke alarm. Be sure all the vents are free of debris.

If necessary, turn off power and use a damp cloth to clean smoke
alarm cover.

IMPORTANT:

Do not attempt to remove the cover or clean inside the smoke
alarm. THIS WILL VOID YOUR GUARANTEE.

REPAIR 

CAUTION: Do not attempt to repair this smoke alarm. 

Doing so will void your guarantee.

If smoke alarm is not operating properly, see “Troubleshooting”. If 
necessary and if still under guarantee, return smoke alarm to Kidde.
Pack it in a well-padded carton and send, postage prepaid to Kidde
address at the end of this manual.

If the smoke alarm is no longer under guarantee, have a qualified
electrician replace the smoke alarm immediately with a comparable
Firex smoke alarm.

PRACTICE FIRE SAFETY

If the smoke alarm sounds its alarm horn, and you have not 
pushed the test button, it is warning of a dangerous situation. 
Your immediate response is necessary. To prepare for such 
occurrences, develop family escape plans, discuss them with 
ALL household members, and practice them regularly. 

Expose everyone to the sound of a smoke alarm and explain 
what the sound means. 

Decide on TWO exits from each room and an escape route 
to the outside from each exit. 

Teach all household members to touch the door and use an 
alternate exit if the door is hot. INSTRUCT THEM NOT TO OPEN
THE DOOR IF THE DOOR IS HOT.

Teach household members to crawl along the floor to stay below
dangerous smoke, fumes, and gases.

Decide on a safe meeting place for all members to meet outside the
building.

WHAT TO DO IN CASE OF A FIRE 

1. Don’t panic; stay calm.

2. Leave the building as quickly as possible. Touch doors to feel if

they are hot before opening them. Use an alternate exit if neces-
sary. Crawl along the floor, and DO NOT stop to collect anything. 

3. Meet at a pre-arranged meeting place outside the building. 

4. Call the fire brigade (Dial 999) from OUTSIDE the building.

5. DO NOT GO BACK INSIDE A BURNING BUILDING. Wait for 

the fire brigade to arrive. 

These guidelines will assist you in the event of a fire. However, to
reduce the chance that fires will start, practice fire safety rules and
prevent hazardous situations

6

!

1227-7201-00_EN_V4:_  2012.3.29  9:46 AM  Page 6

Summary of Contents for KF1

Page 1: ...READ AND SAVE THESE INSTRUCTIONS W A R N I N G DO NOT paint or cover the smoke alarm with tape This smoke alarm should be out of the reach of children AC smoke alarms require constant 230V AC 50Hz po...

Page 2: ...can only sound their alarms when they detect smoke Smoke alarms detect combustion particles in the air They do not sense heat flame or gas This smoke alarm is designed to give audible warning of a dev...

Page 3: ...ent Building Regulations and or BS5839 Pt6 current I E E Regulations CAUTION Alarm should not be exposed to dripping or splashing HOW TO INSTALL THIS SMOKE ALARM DANGER ELECTRICAL SHOCK HAZARD Turn of...

Page 4: ...ARM INTERCONNECTING SMOKE ALARMS Use 1 5mm2 minimum solid or stranded cable with a rating of 230V When interconnecting maximum cable length between any two is 450 m for 1 5mm2 or 1200 m for 2 5mm2 20...

Page 5: ...Test button NOTE If smoke alarms are interconnected all smoke alarms should sound an alarm within three seconds after any test button is pushed and the tested smoke alarm sounds 3 If smoke alarm does...

Page 6: ...o not attempt to remove the cover or clean inside the smoke alarm THIS WILL VOID YOUR GUARANTEE REPAIR CAUTION Do not attempt to repair this smoke alarm Doing so will void your guarantee If smoke alar...

Page 7: ...onnector 3 Clean smoke alarm Smoke alarm beeps about 1 Turn off power and once a minute replace battery See KF1 and KF2 only in the MAINTENANCE AND CLEANING section 2 Clean smoke alarm KF1R and KF2R o...

Page 8: ...ASE SHALL KIDDE BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY ITS NEGLIGENCE OR F...

Reviews: