• In an area where the temperature may fall below -20ºF or rise above 100ºF.

• Near fluorescent lights – electronic "noise" may cause nuisance alarms.

• Heat alarms are not to be used with detector guards unless the combination

(alarm and guard) have been evaluated and found suitable for that purpose.

4. INSTALLATION INSTRUCTIONS

WIRING REQUIREMENTS

• This smoke alarm should be installed on a U.L. listed or recognized junction

box. All connections should be made by a qualified electrician and all wiring
used shall be in accordance with articles 210 and 300.3(B) of the U.S. National
Electrical Code ANSI/NFPA 70, NFPA 72 and/or any other codes having jurisdic-
tion in your area. The multiple station interconnect wiring to the alarms must
be run in the same raceway or cable as the AC power wiring. In addition, the
resistance of the interconnect wiring shall be a maximum of 10 ohms.

• The appropriate power source is 120 Volt AC Single Phase supplied from a

non-switchable circuit which is not protected by a ground fault interrupter.

• WARNING:This alarm cannot be operated from power derived from a square

wave or modified square wave inverter. These type of inverters are sometimes
used to supply power to the structure in off grid installations, such as solar or
wind derived power sources. These power sources produce high peak voltages
that will damage the alarm.

WIRING INSTRUCTIONS FOR AC QUICK CONNECT HARNESS

CAUTION! TURN OFF THE MAIN POWER TO THE CIRCUIT BEFORE WIRING
THE ALARM.

• For alarms that are used as single station, DO NOT CONNECT THE RED WIRE

TO ANYTHING. Leave the red wire insulating cap in place to make certain that
the red wire cannot contact any metal parts or the electrical box.

• When alarms are interconnected, all interconnected units must be powered

from a single circuit.

• A maximum of 24 Kidde/Lifesaver devices may be interconnected in a multiple

station arrangement.  The interconnect system should not exceed the NFPA
interconnect limit of 12 smoke alarms and/or 18 alarms total (smoke, heat,
carbon monoxide, etc.).  With 18 alarms interconnected, it is still possible to
interconnect up to a total of 6 remote signaling devices and/or relay modules.

 

Summary of Contents for HD135F

Page 1: ...non specified equipment from another manufacturer into an existing Kidde system could result in nuisance alarming failure to alarm or damage to one or all of the devices in the interconnect system Re...

Page 2: ...IONS 2 RECOMMENDED LOCATIONS OF ALARMS 3 LOCATIONS TO AVOID 4 INSTALLATION INSTRUCTIONS 5 OPERATION AND TESTING 6 FALSE ALARMS 7 MAINTENANCE 8 LIMITATIONS OF HEAT ALARMS 9 GOOD SAFETY HABITS 10 NFPA P...

Page 3: ...ese cases the alarm should be mounted on an inside wall If the alarm cannot be located in the center of the room an off center location can be used on the ceiling When off cen ter mounting an alarm on...

Page 4: ...d to present stan dards extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof This may create a thermal barrier which can prevent the heat from...

Page 5: ...ot protected by a ground fault interrupter WARNING This alarm cannot be operated from power derived from a square wave or modified square wave inverter These type of inverters are sometimes used to su...

Page 6: ...equired by local codes avail able at all electrical supply stores and most hardware stores FIGURE 4 INTERCONNECT WIRING DIAGRAM WIRES ON ALARM HARNESS CONNECTED TO Black Hot Side of AC Line White Neut...

Page 7: ...s near each mounting hole in the trim ring to help you select the correct mounting holes see figure 5 4 Pull the AC QUICK CONNECTOR through the center hole in the trim ring and mount the ring making s...

Page 8: ...he bat teries Use long nose pliers to pull the pin out of the hole It is now possible to remove the alarm from the trim ring After installation TEST your alarm by pressing and holding the test button...

Page 9: ...iginating alarm or alarm being tested will flash rapidly All other units in the interconnect sys tem will sound an alarm but their red LED s will NOT flash rapidly The green LED is located under the o...

Page 10: ...ss squeeze the locking arms on the sides of the Quick Connector while pulling the connector away from the bottom of the alarm see section 4 figure 6 BATTERY INSTALLATION AND REMOVAL To replace or inst...

Page 11: ...TO FOLLOW BATTERY INSTALLATION INSTRUCTIONS PRINTED ON THE INSIDE OF THE BATTERY DOOR AND USE ONLY THE BATTERIES SPECIFIED USE OF DIFFERENT BATTERIES MAY HAVE A DETRI MENTAL EFFECT ON THE SMOKE ALARM...

Page 12: ...E OF THE SPECIFIED TYPE IN GOOD CONDI TION AND INSTALLED PROPERLY AC POWERED ALARMS WILL NOT OPERATE IF AC POWER HAS BEEN CUT OFF SUCH AS BY AN ELECTRICAL FIRE OR AN OPEN FUSE ALARMS MUST BE TESTED RE...

Page 13: ...o test your plan before an emergency You may not be able to reach your children It is important they know what to do Current studies have shown smoke alarms may not awaken all sleeping individuals and...

Page 14: ...nity of the sleeping rooms 3 On each level of the dwelling unit including basements Exception In existing one and two family dwelling units approved smoke alarms powered by batteries are permitted Smo...

Page 15: ...y of but outside of the bed rooms and heat or smoke alarms in the living rooms dining rooms bedrooms kitchens hallways attics furnace rooms closets utility and storage rooms base ments and attached ga...

Page 16: ...LARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF THE HEAT ALARM AND IN NO CASE SHALL KIDDE SAFETY OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATION...

Page 17: ...consecuencia alarmas molestas fallas de la alarma o da os a uno o todos los dispositivos del sistema interconectado Consulte la Gu a del usuario que se entrega con cada producto Kidde para conocer lo...

Page 18: ...SERVICIO Y GARANT A No intente reparar esta alarma de calor Consulte las instrucciones en la Secci n 11 para obtener informaci n sobre servicio 1 ESPECIFICACIONES N mero de modelo HD135F CA 120 VCA 60...

Page 19: ...lg 30 5 cm bajo el cielo raso consulte la Figura 1 Instale las alarmas de calor en cielos rasos con pendiente a dos vertientes o catedral a 3 pies 0 9 m o menos del punto m s alto medido horizontalmen...

Page 20: ...si observa que las paredes externas y el cielo raso est n calientes o fr os instale la alarma en una pared interna ADVERTENCIA PRUEBE EL FUNCIONAMIENTO DE LA ALARMA DE CALOR DESPU S DE QUE SU VEH CULO...

Page 21: ...una pieza de metal ni con la caja el ctrica Cuando las alarmas est n interconectadas todas las unidades interconectadas deben activarse desde un circuito nico En una configuraci n de m ltiples estacio...

Page 22: ...de la alarma 2 Despu s de seleccionar la ubicaci n adecuada para la alarma contra humo como se describe en la Secci n 2 y de conectar los cables de CONEXI N R PIDA DE CA seg n se describe en las INSTR...

Page 23: ...seguridad contra la manipulaci n indebida para cambiar las bater as Use un alicate de punta larga para sacar el pasador del orificio Ahora puede sacar la alarma del anillo de ajuste Despu s de la inst...

Page 24: ...defectuosa en cuyo caso debe devolverla para que sea reparada CONSULTE LA SECCI N 12 6 FALSAS ALARMAS Para evitar las falsas alarmas NO LA USE EN LUGARES EN DONDE LA TEMPERATURA AMBIENTE SUPERE LOS 10...

Page 25: ...S LO LAS BATER AS QUE SE ESPECIFICAN EL USO DE BATER AS DIFERENTES PUEDE TENER UN EFECTO PERJUDICIAL EN LA ALARMA CONTRA HUMO LIMPIEZA DE SU ALARMA LA ALARMA SE DEBE LIMPIAR UNA VEZ AL A O COMO M NIMO...

Page 26: ...ECTAR ENTRE S Y CON LAS ALARMAS DE CALOR AUNQUE LAS ALARMAS DE CALOR CUANDO SE COMBINAN CON LAS ALARMAS DE HUMO PUEDEN AYUDAR A SALVAR VIDAS AL PROPORCIONAR UNA OPORTUNA ADVERTENCIA DE UN INCENDIO NO...

Page 27: ...a y dos viviendas unifamiliares 2 Afuera de cada dormitorio y pr ximo a los mismos 3 En cada nivel de la vivienda unifamiliar incluyendo el s tano excepto Se permite el uso de alarmas contra humo acci...

Page 28: ...E SAFETY O DE CUALQUIER SOCIEDAD DE CONTROL O SUBSIDIARIA QUE SURJA DE LA VENTA DE ESTA ALARMA O SEG N LOS T RMINOS DE ESTA GARANT A LIMITADA EN NING N CASO DEBE EXCEDER EL COSTO DEL REEMPLAZO DE LA A...

Reviews: