Note A: 

Maximum coverage established by U.L. is based on providing equal

response time as sprinkler devices spaced at 10-Ft intervals (100 Sq/Ft) on a
smooth ceiling approximately 15 feet high. Higher ceilings may adversely affect
response time and earlier response time may be obtained by reducing the spac-
ing between alarms.

Note B:

Maximum distance is from any wall or ceiling projection extending

down more than 12 inches.

2. RECOMMENDED LOCATION OF ALARMS

• The most favorable mounting location
for a heat alarm is on the ceiling in the
center of the room. At this location the
alarm is closest to all areas of the room
(see figure 3).

EXCEPTION:

When the mounting surface

might become considerably warmer or
cooler than the room, such as a poorly
insulated ceiling, below an unfinished attic,
or an exterior wall. In these cases the alarm
should be mounted on an inside wall.          

•  If the alarm cannot be located in the
center of the room, an off-center location
can be used on the ceiling. When off cen-
ter mounting an alarm on the ceiling,
locate it at a minimum of 4" (10 cm) from
the side wall (see figure 3).

•   If a ceiling mounting location is not fea-
sible the next logical location for mounting
heat alarms is on the side wall. When
mounting the alarm on the wall, use an
inside wall with the top edge of the alarm
at a minimum of 4" (10 cm) and a maxi-
mum of 12" (30.5 cm) below the ceiling
(see figure 1).

• Install Heat Alarms on sloped, peaked or cathedral ceilings at or within 3 ft
(0.9m) of the highest point (measured horizontally). NFPA 72 states: “Smoke
alarms in rooms with ceiling slopes greater than 1 ft in 8 ft (.3m in 2.4m) hori-
zontally shall be located on the high side of the room.”  NFPA 72 states: “A row

(10 cm)

4"

MINIMUM

(10 cm)

4"

CEILING

DEAD AIR

SPACE

SIDE

WALL

MINIMUM

(30.5 cm)

12"

MAXIMUM

BEST

HERE

NEVER

HERE

ACCEPTABLE

HERE

FIGURE 1

FIGURE 2

 

Summary of Contents for HD135F

Page 1: ...non specified equipment from another manufacturer into an existing Kidde system could result in nuisance alarming failure to alarm or damage to one or all of the devices in the interconnect system Re...

Page 2: ...IONS 2 RECOMMENDED LOCATIONS OF ALARMS 3 LOCATIONS TO AVOID 4 INSTALLATION INSTRUCTIONS 5 OPERATION AND TESTING 6 FALSE ALARMS 7 MAINTENANCE 8 LIMITATIONS OF HEAT ALARMS 9 GOOD SAFETY HABITS 10 NFPA P...

Page 3: ...ese cases the alarm should be mounted on an inside wall If the alarm cannot be located in the center of the room an off center location can be used on the ceiling When off cen ter mounting an alarm on...

Page 4: ...d to present stan dards extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof This may create a thermal barrier which can prevent the heat from...

Page 5: ...ot protected by a ground fault interrupter WARNING This alarm cannot be operated from power derived from a square wave or modified square wave inverter These type of inverters are sometimes used to su...

Page 6: ...equired by local codes avail able at all electrical supply stores and most hardware stores FIGURE 4 INTERCONNECT WIRING DIAGRAM WIRES ON ALARM HARNESS CONNECTED TO Black Hot Side of AC Line White Neut...

Page 7: ...s near each mounting hole in the trim ring to help you select the correct mounting holes see figure 5 4 Pull the AC QUICK CONNECTOR through the center hole in the trim ring and mount the ring making s...

Page 8: ...he bat teries Use long nose pliers to pull the pin out of the hole It is now possible to remove the alarm from the trim ring After installation TEST your alarm by pressing and holding the test button...

Page 9: ...iginating alarm or alarm being tested will flash rapidly All other units in the interconnect sys tem will sound an alarm but their red LED s will NOT flash rapidly The green LED is located under the o...

Page 10: ...ss squeeze the locking arms on the sides of the Quick Connector while pulling the connector away from the bottom of the alarm see section 4 figure 6 BATTERY INSTALLATION AND REMOVAL To replace or inst...

Page 11: ...TO FOLLOW BATTERY INSTALLATION INSTRUCTIONS PRINTED ON THE INSIDE OF THE BATTERY DOOR AND USE ONLY THE BATTERIES SPECIFIED USE OF DIFFERENT BATTERIES MAY HAVE A DETRI MENTAL EFFECT ON THE SMOKE ALARM...

Page 12: ...E OF THE SPECIFIED TYPE IN GOOD CONDI TION AND INSTALLED PROPERLY AC POWERED ALARMS WILL NOT OPERATE IF AC POWER HAS BEEN CUT OFF SUCH AS BY AN ELECTRICAL FIRE OR AN OPEN FUSE ALARMS MUST BE TESTED RE...

Page 13: ...o test your plan before an emergency You may not be able to reach your children It is important they know what to do Current studies have shown smoke alarms may not awaken all sleeping individuals and...

Page 14: ...nity of the sleeping rooms 3 On each level of the dwelling unit including basements Exception In existing one and two family dwelling units approved smoke alarms powered by batteries are permitted Smo...

Page 15: ...y of but outside of the bed rooms and heat or smoke alarms in the living rooms dining rooms bedrooms kitchens hallways attics furnace rooms closets utility and storage rooms base ments and attached ga...

Page 16: ...LARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF THE HEAT ALARM AND IN NO CASE SHALL KIDDE SAFETY OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATION...

Page 17: ...consecuencia alarmas molestas fallas de la alarma o da os a uno o todos los dispositivos del sistema interconectado Consulte la Gu a del usuario que se entrega con cada producto Kidde para conocer lo...

Page 18: ...SERVICIO Y GARANT A No intente reparar esta alarma de calor Consulte las instrucciones en la Secci n 11 para obtener informaci n sobre servicio 1 ESPECIFICACIONES N mero de modelo HD135F CA 120 VCA 60...

Page 19: ...lg 30 5 cm bajo el cielo raso consulte la Figura 1 Instale las alarmas de calor en cielos rasos con pendiente a dos vertientes o catedral a 3 pies 0 9 m o menos del punto m s alto medido horizontalmen...

Page 20: ...si observa que las paredes externas y el cielo raso est n calientes o fr os instale la alarma en una pared interna ADVERTENCIA PRUEBE EL FUNCIONAMIENTO DE LA ALARMA DE CALOR DESPU S DE QUE SU VEH CULO...

Page 21: ...una pieza de metal ni con la caja el ctrica Cuando las alarmas est n interconectadas todas las unidades interconectadas deben activarse desde un circuito nico En una configuraci n de m ltiples estacio...

Page 22: ...de la alarma 2 Despu s de seleccionar la ubicaci n adecuada para la alarma contra humo como se describe en la Secci n 2 y de conectar los cables de CONEXI N R PIDA DE CA seg n se describe en las INSTR...

Page 23: ...seguridad contra la manipulaci n indebida para cambiar las bater as Use un alicate de punta larga para sacar el pasador del orificio Ahora puede sacar la alarma del anillo de ajuste Despu s de la inst...

Page 24: ...defectuosa en cuyo caso debe devolverla para que sea reparada CONSULTE LA SECCI N 12 6 FALSAS ALARMAS Para evitar las falsas alarmas NO LA USE EN LUGARES EN DONDE LA TEMPERATURA AMBIENTE SUPERE LOS 10...

Page 25: ...S LO LAS BATER AS QUE SE ESPECIFICAN EL USO DE BATER AS DIFERENTES PUEDE TENER UN EFECTO PERJUDICIAL EN LA ALARMA CONTRA HUMO LIMPIEZA DE SU ALARMA LA ALARMA SE DEBE LIMPIAR UNA VEZ AL A O COMO M NIMO...

Page 26: ...ECTAR ENTRE S Y CON LAS ALARMAS DE CALOR AUNQUE LAS ALARMAS DE CALOR CUANDO SE COMBINAN CON LAS ALARMAS DE HUMO PUEDEN AYUDAR A SALVAR VIDAS AL PROPORCIONAR UNA OPORTUNA ADVERTENCIA DE UN INCENDIO NO...

Page 27: ...a y dos viviendas unifamiliares 2 Afuera de cada dormitorio y pr ximo a los mismos 3 En cada nivel de la vivienda unifamiliar incluyendo el s tano excepto Se permite el uso de alarmas contra humo acci...

Page 28: ...E SAFETY O DE CUALQUIER SOCIEDAD DE CONTROL O SUBSIDIARIA QUE SURJA DE LA VENTA DE ESTA ALARMA O SEG N LOS T RMINOS DE ESTA GARANT A LIMITADA EN NING N CASO DEBE EXCEDER EL COSTO DEL REEMPLAZO DE LA A...

Reviews: