6. Initial Testing and Checking of Alarm

Before powering up/testing CHECK THAT WIRING POLARITY is correct & all
connections are tight. REVERSING POLARITY will fatally damage all inter-
connected alarms, and damage is not covered by the Guarantee. Slide alarm
fully home on base plate before powering up, to prevent arcing across the
contact blades.

Having energised circuit, press and hold the test button again – the alarm should
sound and other interconnected ones also, within a few seconds.

Do this for all alarms.

If any do not sound, isolate mains and recheck cabling.

On optical alarms, if the red L.E.D. blinks every 30-40 seconds and the alarm
chirps in between, it indicates failure of the sensing chamber  - replace alarm. 

Advise the house-holder (if present) as to how to test the alarms.

6

Battery Changing

Loose battery models (battery changing) See section 12

Reconnect mains supply and check green L.E.D. is lit – red L.E.D. will flash intermit-
tently.

GREEN LED

RED LED

A maximum of 24 Kidde devices may be interconnected in a multiple station arrange-
ment. The interconnect system should not exceed 12 Smoke Alarms and/or 18
Alarms total (Smoke, Heat, CO and etc). With 18 alarms interconnected up to 6
alarm accessories (relay modules, visual signaldevice and etc.).

Crossing line and neutral connections or line and interconnect connections will fatally
damage all interconnected alarms invalidating the guarantee.

All interconnected alarms must be powered off the same fuse/circuit breaker.

Total cable length between alarms must not exceed 250m (273yds) and be 1.0mm in
diameter, 3 core and earth (BS6243Y). Wiring must conform to the

IEE regulations - BS7671, or latest edition.

These smoke/heat alarms are Interconnectable with Kidde Rechargeable CO Alarm
models 423D/9hir & 423/9hir.but will not respond to a CO interconnect alarm
signal.These alarms will trigger the interconnected hard wired CO alarms with a
deferential sounder

7. Interconnecting

 Line 

Neutral 

Interconnect (I/O)* 

* Interconnect only — if single alarm installation, leave unconnected the I/O terminal.

These are double insulated products and do not need earthing: never use 

earth conductor to interconnect – use 3 core and earth cable. Use 

 black in 3 core & earth cabling, for interconnect line.

If installing using old cabling (different colors), take great care / follow IEE Reqs.

House Cabling  Refer to IEE Reqs

6

1385-7206-00_R3_V9:-  2011.3.14  5:28 PM  Page 6

Summary of Contents for Fyrnetics Slick 1SFW

Page 1: ...en Way Colnbrook SL3 0HB UK www kiddefyrnetics co uk Kidde Fyrnetics 2008 Electrical rating 230V AC 50Hz 80mA max per alarm maximum 80mA for originating unit with 24 Devices inter connected These alarms may be used with the Kidde Wireless base accesso ry enabling interconnection between alarms wirelessly The Remote Test Hush accessory will also work with alarms on Wireless bases 1385 7206 00 Conte...

Page 2: ...Doing so before hand can cause serious injury Do not install in a dripping water splashing very humid area WARNING This alarm cannot be operated from power derived from a square wave or modified sine wave inverter These types of inverters are sometimes used to sup ply power to the structure in off grid installations such as solar or wind derived power sources These power sources produce high peak ...

Page 3: ...ansferred from the outside to the inside through poorly insulated walls and roof This may create a thermal barrier which can prevent the smoke from reaching an alarm mounted on the ceiling If you are not sure about the insulation in your home or if you notice that the outer walls and ceiling are either hot or cold install the alarm on an inside wall In such homes install the smoke alarm with the t...

Page 4: ... 3ft of the following the door to a kitchen the door to a bathroom containing a tub or shower ceiling or whole house ventilat ing fans orother high air flow areas Kitchens Normal cooking may cause nuisance alarms Only Heat Alarms are suitable for use in Kitchens they should also be fitted in integral garages Smoke alarms are not to be used with detector guards unless the combination alarm and guar...

Page 5: ...lace cover by locating leg as shown and then gently levering clip to full close If necessary the alarm can be unclipped from its base plate by depressing where shown Figure b above and just the base installed at 1st fix The alarm can then be slid on to the hinge and then slid home as illustrated below 2 d 5 Loose Battery Models The alarm will not locate without a battery in the compartment Never r...

Page 6: ...Smoke Alarms and or 18 Alarms total Smoke Heat CO and etc With 18 alarms interconnected up to 6 alarm accessories relay modules visual signaldevice and etc Crossing line and neutral connections or line and interconnect connections will fatally damage all interconnected alarms invalidating the guarantee All interconnected alarms must be powered off the same fuse circuit breaker Total cable length b...

Page 7: ... interconnected only triggering alarm will have this state If interconnected to other alarms only the triggering alarm will have a rapidly flashing L E D On optical alarms if the red L E D blinks every 30 40 seconds and the alarm chirps in between it indicates failure of the sensing chamber Householders should consult Owner s Manual or installer landlord The alarm sounder and flashing L E D will r...

Page 8: ...tification to occupants of the need to escape followed by the appropriate egress actions by those occupants Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal fires Victims can be involved with the fire too old or young or physically or mentally impaired such that they cannot escape even when warned early enough that escape should be ...

Page 9: ...ontinuously the see section 5 to replace battery if applicable If unit has rechargeable battery or problem persists after installing a new bat tery contact customer service See parts 1a and 1b above Have installer re check wiring if Green LED is illuminated but alarm does not appear to function If no Green LED check consumer unit Alarm will still function on battery power if battery is in servicea...

Page 10: ...y Colnbrook SL3 0HB UK The terms of this guarantee will not apply in the following circumstances If alarm has been damaged modified neglected dismantled contaminated abused or altered after the date of purchase or if it fails to operate due to incorrect selection siting installation maintenance or inadequate AC or DC electrical power or damage caused by failure to abide by the instructions supplie...

Reviews: