background image

IF THE TAMPER RESIST FEATURE HAS BEEN ACTIVATED, REFER
TO TAMPER RESIST FEATURE DESCRIPTION ON PAGE 19 FOR
REMOVAL INSTRUCTIONS

.

Remove the alarm from the mounting bracket by rotating the
alarm in the direction of the “OFF” arrow on the cover. To
disconnect the AC power harness, squeeze the locking arms on
the sides of the Quick Connector while pulling the connector
away from the bottom of the alarm.

If any form of battery failure is detected the red LED light will
flash and the unit will “chirp” one time, followed by the
warning message 

“LOW BATTERY! PILE FAIBLE!”

. This cycle will

occur once every minute for the first hour. After the first hour,
the red LED light will continue flashing accompanied by the

chirp only sound

every 60 seconds. The voice message 

“LOW

BATTERY! PILE FAIBLE!”

will sound once every fifteen minutes

during the chirp only cycle, and will continue for at least seven
days.

If the red LED light flashes along with a chirp every 30
seconds, and is not followed by the voice message “LOW
BATTERY! PILE FAIBLE!” 
as described above, your unit has
malfunctioned.

Call our toll free Consumer Hotline at 

1-800-880-6788 for instructions on how to return the unit.

CAUTION: YOUR SMOKE/CO ALARM IS SEALED AND THE
COVER IS NOT REMOVABLE!

Note: If battery carrier tamper resist feature has been activated
it will need to be deactivated in order to change the battery.
Refer to page 19 “Battery Carrier Tamper Resist Feature” for
instructions.

Alarm Removal

Battery Replacement