17
10. Product Specifica0ons
Power
Sealed in lithium ba0ery
Sensor
Electrochemical CO Sensor
Accuracy
Depending on the ambient condi/on (temperature, humidity) and the
condi/on of the sensor, the alarm readings may vary. The digital readings
tolerances are:
Ambient: 27°C +/- 12°C (80°F +/- 10°F), atmospheric pr/- 10%,
40% +/- 3% rela/ve humidity
Temperature Range
Opera/ng range: 0°C to 40°C
Humidity
Up to 90% non-condensing
Alarm Sound
At Least 85dB (A) at 1 metre @ 3.4 +/- 0.5 KHz pulsing alarm
Size and weight
Weight: 160g
Dimensions: 118mm x 70mm x 40mm
NOTE:
Constant exposures to extreme temperatures or humidity can reduce battery life
.
End of Life
- This alarm will chirp twice every 30 seconds and the red LED flashes twice after at
least 10 years operation to let you know it has reached its end of life.
2539-7201-05_10LLCO_10LLDCO_V1:_ 2016.11.2 9:06 AM Page 17