background image

1. To insure aesthetic alignment of the

alarm with the hallway or wall, the “A”
line on the mounting bracket should be
parallel with the hallway when ceiling
mounting or horizontal when wall
mounting.

2. After selecting the proper smoke alarm

location as described in Section 1, attach
the mounting bracket to the ceiling as
shown in Figure 3. For wall mounting
see Figure 4. Place the mounting plate
on the wall; be sure the “A” line is
horizontal (parallel to the floor). Use the screws and wall plugs provided to secure
the mounting bracket (use 3/16” drill bit for wall plugs).

3. This alarm has batteries permanently sealed inside the alarm no battery installation is

necessary.

TAMPER RESIST FEATURE

Smoke Alarm Tamper Resist Feature

This alarm is equipped with a tamper resist feature that helps prevent someone from
removing the unit from the mounting bracket. When activated, it can be very effective
in preventing smoke alarm removal or tampering.

NOTE:

The tamper resist feature is automatically engaged whenever the alarm is

mounted to the mounting bracket.

Rotate the alarm onto the mounting bracket
until you hear the tamper resist tab snap
into place, locking the alarm on the
mounting bracket. Using the tamper resist
feature will help deter children and others
from removing the alarm from the bracket.
NOTE: To remove the alarm when the
tamper resist tab is engaged, press down on
the tamper resist tab using a tool such, as a
small screwdriver, and rotate the alarm in
the direction indicated by the arrows on the
cover of the alarm (see Figure 7).

FIGURE 7

A

A

FIGURE 4

When mounting
in a hallway, the
“A” line should
be parallel with
the hallway.

A

A

Alignment Marks

(”A” Line) on

Mounting

Bracket

FIGURE 5

When wall
mounting, the
“A” line should
be horizontal.

3.INSTALLATION INSTRUCTIONS

CAUTION: THIS UNIT IS SEALED (INCLUDING THE BATTERIES). THE COVER IS
NOT REMOVABLE!

Install

Remove

FIGURE 6

A

A

0910-7207-03_R1.qxd:_  2009.8.13  6:52 PM  Page 4

Summary of Contents for 0910UK

Page 1: ...sooner than ionisation alarms Home fires develop in different ways and are often unpredictable For maximum protection Kidde recommends that both Ionisation and Photoelectric alarms be installed Insta...

Page 2: ...an prevent the smoke from reaching an alarm mounted on the ceiling If you are not sure about the insulation in your home or if you notice that the outer walls and ceiling are either hot or cold instal...

Page 3: ...nvironments In dusty areas Dust particles may cause nuisance alarm or failure to alarm In very humid areas Moisture or steam can cause nuisance alarms In areas where the Relative Humidity RH is above...

Page 4: ...ted it can be very effective in preventing smoke alarm removal or tampering NOTE The tamper resist feature is automatically engaged whenever the alarm is mounted to the mounting bracket Rotate the ala...

Page 5: ...dness 85 decibels of the alarm always stand an arms length away from the unit when testing 4 TESTING Test by pushing the test button on the cover and holding it down for a minimum of 5 seconds or unti...

Page 6: ...hire SL3 OHB This warranty shall not apply to the smoke alarm if it has been damaged modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance THE LIA...

Page 7: ...at 01753 685148 or contact us at our website at www kiddesafetyeurope co uk Kidde Safety Europe Mathisen Way Colnbrook Slough Berkshire SL3 OHB UK Copyright Walter Kidde Portable Equipment 2005 All Ri...

Reviews: