4
ZX AMPLIFIERS
AUTO
TURN ON
+12V DC AUDIO
OFFSET
LO
HI
REMOTE BASS
INPUT
SPKR +
SPKR -
OUTPUT
INPUT
SENSITIVITY
L
L
R
R
+
–
MONO OPERATION
minimum impedance of 2 ohms
signal in
signal out
woofer
OPERATION
AUTO
TURN ON
+12V DC AUDIO
OFFSET
LO
HI
REMOTE BASS
INPUT
SPKR +
SPKR -
OUTPUT
INPUT
SENSITIVITY
L
L
R
R
Automatic Turn-On Selection:
The ZX series offers three different automatic turn-on modes that can be
selected on the end panel; +12V, DC Offset, and Audio. Using either the DC Offset or Audio mode causes the
REM terminal to have +12V out for turning on additional amplifi ers.
•
Remote Turn-On: Set the switch to +12V to use the remote turn-on lead from your source unit. Run 18
gauge wire from the Remote Turn-On Lead on your source unit to the terminal labeled REM between the
amplifi er’s positive and negative power terminals. This is the preferred automatic turn-on method.
•
DC Offset Turn-On: If Remote Turn-On is not an option, the next best setting is DC Offset. The DC Offset
mode detects a 6V DC offset from the HI-Level speaker outputs when the source unit has been turned on.
• Signal Sense Turn-On: The Audio setting is the fi nal alternative for Automatic turn-on. This is a Signal Sense
turn-on method that detects the incoming audio signal from your source unit and automatically turns on the
amp. This turn-on method will not work properly if the input gain control is not set appropriately.
NOTE:
Speaker terminals on the ZX2500.1 are on the opposite end panel.