Inline fuse
RED
BLACK
Ring terminal
FAN
Note:
If permanently installing the charger a 40 Amp fuse will be required to be fitted on
the positive (red) wire.
Error Code
Fault
lamp
Cause
Remedy
Polarity Reverse
/ Output Short
Short circuit
or reverse
connection of
the clips.
Check clips are not
touching each other
OR Check the clips are
correctly connected to
the battery.
Non Battery
Link
Non battery link.
Please choose the
right battery type for
connection.
Over Voltage
The 12V lithium
battery voltage
is above 15.5V.
Over
Temperature
Internal
temperature
is above
O
O
65 C +/-5 C.
Turn off charger and
allow to cool.
Faulty
Battery
Bulk charging
has timed out
and stopped after
10 hours.
Battery is faulty and
may need to be
replaced.
Disconnect the
charger and check
the battery voltage.
This charger is
suitable for 12V
Batteries only.
Power on
lamp
Stage
lamp
(Step 2
lamp)
There are error codes that may be displayed. These will be displayed in the following way:
FAULT CODES