POWER ON LAMP:
If the power lamp is lit with a:
1.steady light
The mains is connected to a wall socket
2. Flashing light
The charger has entered the energy saving mode,
This happens if the charger hasn’t been connected to a battery within 2 minutes of being
turned on.
FAULT LAMP
If the fault lamp is solid,check the following
Has the charging stage been interrupted in stage 1,2 or 4?
Restart the charger by pressing the on/off button.
If the charger is still being interrupted check the battery.
STEP 1.
The battery may be faulty and may need replaced.
STEP 2.
Bulk charging has timed out and stopped after 10 hours of being charged.(replace
battery)
Step 3.
If fault light is flashing chargers internal temperature is higher 65 oC (disconnect
charger from battery and allow fan to cool charger)
5