Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
5
Perpendicular 24”-30” Deep
Worksurface Connections with
74P Edge
Note:
When 24” & 30” deep 74P
edge worksurfaces are installed
perpendicular to each other, a
worksurface splice plate must be
installed between the adjacent
worksurface pairs as illustrated
to keep worksurface tops aligned.
The splice plate, when properly
installed will span over the
beveled gap (Figure 4).
1. Install standard cantilever brackets
to Unite panels as outlined in
steps 1-4 (page 3) to the locations
outlined in your space-planning
layout (Figure 1).
2. Carefully place worksurfaces
onto cantilever brackets per
space planning layout and align
mounting holes of brackets to
pre-drilled holes in underside of
worksurfaces. Secure using two
#12 x
3
/
4
” screws per bracket.
Take care to not over-tighten the
screws.
3. To keep worksurfaces level,
install a small splice plate
between adjacent worksurfaces
as illustrated. Use the splice plate
mounting holes as a template
and drill
1
/
8
” diameter holes to
not more than
1
/
2
” deep to avoid
damaging surface. Install small
splice plate to underside of
worksurfaces using four
#12 x
3
/
4
” screws. Take care to not
over-tighten screws (Figure 4).
”
#12 x /
3
4
”
screws