28 

10 July 2000 

STANDARD:

   Select between NTSC and PAL video standards 

 

NOTCH:

  Select NOTCH FILTER on or off 

 

COMB:

  Select COMB FILTER on or off 

 

 

SEQUENCING 
 

Sequencing is the function of performing live transitions between pre-stored key frames.  You 
may program and initiate key frame sequences based on the 10 available key frame registers (00 
through 09).   

 

Some common uses of sequencing include: transitioning from a full screen image to a 
compressed image for an “over-the-shoulder” shot; or from a full screen to a compressed image 
to reveal a scroll on-screen (stock tickers, school closings, news tickers, weather alerts); or from 
compressed image to compressed image for on-screen special effects.  The uses of sequencing 
are limited only by your imagination.  Sequences can include borders with transitioning colors, 
aspect ratio changes, position changes, size changes; they can also be reversed, paused, looped or 
continued. 
 

 

GPI MODES 

 

FTB OFF:

  Will cause image to fade from black when a GPI pulse is received. 
 

FTB ON:

  Will cause the image to fade to black when a GPI pulse is received. 

 

FTB TOGGLE:

  Will cause the image to fade to black on the first receipt of a GPI pulse; and 

fade from black on the second receipt of a GPI pulse 

 

FTB FOLLOW:

  Will cause the image to fade to black and remain there while the GPI signal is 

LOW (0.0 to 0.4 VDC); the image will immediately fade from black when the GPI signal returns 
high (4.0 to 5.0 VDC). 
 

MIX OFF:

 Will cause image to mix in (background with insert video) when a GPI pulse is 

received. 
 

MIX ON:

  Will cause the image to mix out (background video only) when a GPI pulse is 

received. 

 

MIX TOGGLE:

  Will cause the image to mix out on the first receipt of a GPI pulse; and mix in 

on the second receipt of a GPI pulse. 
 

Summary of Contents for MegaHertz The Protector

Page 1: ...al change 0 20 Nov 00 PRELIMINARY Due to possible design modifications the descriptions and technical data in this manual are subject to change without prior notice For technical assistance or service...

Page 2: ...devices in former installations it replaces a separate timer device with its own graphical user interface GUI event controller it replaces a separate distribution amplifier with its own included distr...

Page 3: ...connections see fig 1 overall 2 video 3 PC and 4 GPI Provide 115 VAC main power to the unit via the provided ground isolation power cord see fig 1 CAUTION Ensure the unit is mounted securely by all fo...

Page 4: ...8 9 10 1 2 3 4 5 6 7 8 9 10 GPO GPI LOOP GPI CONNECTIONS In a Contact Closure System For GPI 1 Loop Pin 1 to Pin 9 For GPI 2 Loop Pin 3 to Pin 9 Contact Closure GPI 1 GPI 2 Pin 10 Pin 2 Pin 10 Pin 4...

Page 5: ...l MegaHertz Keywest Technology 14563 W 96th Terrace Lenexa Kansas 66215 800 331 2019 www keywesttechnology com 5 10 July 2000 PS2 Mouse Keyboard USB dual Keyboard or Mouse LAN COM1 Video Figure 3 Typi...

Page 6: ...relay that will make a low 0V or simple ground The Protector reacts to the GPI based on how you program it in the Event Controller covered later in this manual Most contact closure outputs from the a...

Page 7: ...u will need to connect an SVGA 800 x 600 progressive scan monitor a mouse PS2 or USB and a keyboard Also to utilize the full function of the unit you should take the time to connect it to your Local A...

Page 8: ...reground and background video The unit also features two distributed background outputs for use in other areas of your system one of which is used as a genlock signal for the foreground video With the...

Page 9: ...COMM PORT For virtually all setups select COMM 1 this is the default if you simply press enter at this point and click OK Note if the Protector has been configured to auto start this page may not be s...

Page 10: ...N Use this form to adjust your proc amp settings color bright contrast hue and timings This form also contains controls for the remaining features of the Protector video processing board set The Prote...

Page 11: ...ver settings you ve changed will be the new default state If you have made changes that you wish to save simply click STORE PROC to store the proc amp settings and then click STORE POR to store the de...

Page 12: ...g processor board function In general for the stock ticker job you will use only Keyframe 0 and Keyframe 1 Keyframe 0 is preset at the factory to be a full screen no borders and no crop start keyframe...

Page 13: ...the stock ticker job but if you wish to test drive you ll need to squeeze the foreground video down some and move it so that all 4 edges are visible You can then play with the border and crop settings...

Page 14: ...n s menu bar This screen is a small sized screen with a blue background that will allow you to manually create a transition from the current keyframe or video state to a new state over a time that you...

Page 15: ...e In the GUI you want only GPI 1 to be used and you have two states in which the GPI should be set GPI 1 Sequence Follow and GPI 1 Off As you will see in the Event Controller section of this manual GP...

Page 16: ...ossible time you may want to use the GPIO screen is during special coverage from the network It has occurred during erratic market swings that the network ran the ticker after normal hours and through...

Page 17: ...563 W 96th Terrace Lenexa Kansas 66215 800 331 2019 www keywesttechnology com 17 10 July 2000 EVENT CONTROLLER To access the EVENT CONTROLLER click on EVENTS on a main screen A blue background event c...

Page 18: ...full screen when no national ticker is present This makes programming very simple You will program EVENT 1 to send the Protector GPI 1 into SEQUENCE FOLLOW mode during ticker times You will then progr...

Page 19: ...0 AM for this example but you can set it to any desired time for your locale Change the time in this EVENT TIME box by placing the cursor over the hours minutes seconds or AM PM consecutively Use the...

Page 20: ...T 1 10 box Since we are setting up the on condition you will want to select GPI 1 SEQUENCE FOLLOW Ignore the other options they aren t necessary for this ticker protector job Review the white boxes at...

Page 21: ...on this form fig 18 The information you entered in the white boxes should now be transposed to the EVENT CONTROLLER EVENT 1 line The numbered box to the left of EVENT 1 line should now be green this...

Page 22: ...you ll only have to adjust a couple of them EVENT DATE should still be de selected if not de select it remove the checkmark fig 20 EVENT TIME will have to change Using the same method you used to set...

Page 23: ...00 331 2019 www keywesttechnology com 23 10 July 2000 SELECTED EVENT needs to be changed Select GPI 1 OFF for this box now fig 23 Click the SET button to access the event enter screen This time select...

Page 24: ...their left illuminated green fig 25 Is this all correct If so let s move on to see it work if not backtrack through the above steps and make the necessary corrections In the lower right corner of the...

Page 25: ...mpress revealing a background video bottom 1 3 a ticker If you perform the test at a time programmed as GPI 1 OFF you should be able to short the contact closure wires manually and the Protector will...

Page 26: ...t to manipulate an image via aspect ratio control for a perfect fit on any screen or they may display multiple images on one screen for teleconferencing training and before after effects TRANSITION BU...

Page 27: ...order color value 00 15 KEY when the LCD indicates this option rotate the encoder to toggle between the following KEY options INSERT Fills background area not covered by compressed video signal with g...

Page 28: ...ses of sequencing are limited only by your imagination Sequences can include borders with transitioning colors aspect ratio changes position changes size changes they can also be reversed paused loope...

Page 29: ...l immediately unfreeze when the GPI signal returns high 4 0 to 5 0 VDC SEQ BEG Will cause the unit to display the previous START mode keyframe when a GPI pulse is received SEQ REV Will cause the unit...

Page 30: ...WER Input 110 220 VAC Manual Switch Internal VIDEO PROCESSOR Frequency Response 4 5MHz Luma 5 5MHz Chroma minimum Filtering Notch Comb Raster Size per Field 720 pixels by 242 lines Input Formats Compo...

Page 31: ...Protector Operation Manual MegaHertz Keywest Technology 14563 W 96th Terrace Lenexa Kansas 66215 800 331 2019 www keywesttechnology com 31 10 July 2000...