Step 3. Select software license type (Optional) 

The PX0109A Quick I/V Measurement Software For PXIe Precision SMU is recommended for easy and 
quick I/V measurement. Because it supports various license type, select the appropriate one for your 
purpose. Please visit: www.keysight.com/find/px0109a in detail. 

Product 

License type 

License term (36 months subscription) 

License & support 

PX0109A 

Node-locked (fixed) 

R-X45-001-Y 

Transportable 

R-X45-004-Y 

USB Portable

1

 

R-X45-005-Y 

Floating (single site) 

R-X45-002-Y 

Floating (single region)  R-X45-006-Y 

Node-locked (fixed) 

R-X45-001-Y 

1. 

USB portable license requires a certified USB dongle (available for  additional purchase. Keysight part number 
PX0100-D10) 

 

Step 4. Select a calibration plan 

Step 4-1. Select a relevant calibration services plan (optional) 

Factory calibration and certification of calibration comes as standard. The optional ISO 17025 (not 
accredited), ANSI Z540, and commercial calibration certificate with test data are available as follows: 

Description

 

Product number 

Additional information 

Calib uncerta guardbanding 
(not accredited) 

M9602A-1A7/ 
M9603A-1A7 

Calibration certificate with 
measurement results are available 
only at time of purchase 

ANSI Z540-1-1994 calibration 

M9602A-A6J/ 
M9603A-A6J/ 

Calibration certificate with 
measurement results are available 
only at time of purchase 

Commercial calibration certificate with test 
data 

M9602A-UK6/ 
M9603A-UK6 

Calibration certificate with 
measurement results are available 
only at time of purchase 

 

Step 4-2. Select recalibration service plans (optional) 

The following options are available. If you need other options 

 for example, the standard compliant 

calibration option 

 please contact your local Keysight office for availability. 

Description

 

Product number 

Calibration plan 

 return to Keysight 

 3 years 

R-50C-011-3 

Calibration plan 

 return to Keysight 

 5 years 

R-50C-011-5 

 

Summary of Contents for M9602A

Page 1: ...ptions and associated accessories This guide provides step by step instructions to help you configure the product to meet the desired test requirements Model number M9602A PXIe SMU 15 MSa s 1 pA 60 V...

Page 2: ...hort bar 1ea Short bar to connect low terminals to chassis common orderable part number is M9601 87001 includes 5 pcs Connector terminal block 2 5 mm 6 terminal 1ea Connector terminal block to connect...

Page 3: ...1 High current triaxial cable2 Triaxial to SMB cable3 50 s or DC High current triaxial cable High current triaxial cable Triaxial to SMB cable Two wire High current triaxial cable NA NA 1 A low induct...

Page 4: ...connection is required for low current measurement 10 nA or less measurement Do not connect the outer shield or Low Force to the chassis frame ground of the DUT when M9603A is grounded Figure 2 Connec...

Page 5: ...NC f adaptor instead PX0105A 001 002 Low inductance BNC cable 1 5 m 3 m 1 High force N1254A 106 Triaxial m to BNC f adaptor 1 Used with PX0105A Four wire connection for pulse 50 s or DC Figure 3 shows...

Page 6: ...e 4 shows the connection for 2 wire connection For this configuration select the items shown in Table 3 Table 3 Required items for 2 wire connection Product number Description Qty Note PX0104A 001 002...

Page 7: ...X0101A 001 or 002 BNC to ferrule terminal cable with a connector terminal block to connect the M9602A M9603A s interlock pins to it For more detailed information please refer to the Keysight M9602A M9...

Page 8: ...tion of calibration comes as standard The optional ISO 17025 not accredited ANSI Z540 and commercial calibration certificate with test data are available as follows Description Product number Addition...

Page 9: ...Connection between M9602A M9603A and your DUT Two wire connection or four wire connection If you are measuring very small resistances or applying a very large current you should use the four wire mea...

Page 10: ...urements 1 nA requires a guarding to prevent leakage through the measurement cable Figure 7 illustrates a simplified overview of the guarding technique Guarded measurements require the use of triaxial...

Reviews: