![Keysight Technologies E6650AU-TRX Installation Note Download Page 5](http://html1.mh-extra.com/html/keysight-technologies/e6650au-trx/e6650au-trx_installation-note_1961834005.webp)
Installation Note E6650-90013
5
Installation Procedure
Installation Procedure
CAUTION
Electrostatic discharge (ESD) can damage or destroy electronic components.
All work on electronic assemblies should be performed at a static-safe
workstation. Observe proper procedures for performing static-safe work.
The E6650A instrument has and Impact cover and face plate panel which cover access to the TRX
modules. The face plate panel and Impact cover frame needs to be removed to perform the module
addition. The following steps are based on the E6650A being a 2 up system.
Remove Face Plate Panel
1.
. Use the #1 Phillips screwdriver to loosen the 10 screws
(1)
on the edge of
the face plate panel till they spin freely. Use the T-10 TORX driver to remove the 4 screws
(2)
in the middle of each TRX module. Then remove the 2 screws
(3)
on the Controller panel and
the Reference panel. Remove the face plate panel.
Figure 1
Face Plate Panel Screws