background image

Notices

© 

Keysight Technologies

 

1991-2020

No part of this manual may be 

reproduced in any form or by any 

means (including electronic storage 

and retrieval or translation into a 

foreign language) without prior 

agreement and written consent from 

Keysight Technologies, Inc. as 

governed by United States and 

international copyright laws.

Trademark Acknowledgments
Manual Part Number

16089-90030

Edition

Edition 7, January 2020

Printed in Malaysia

Published by:

Keysight Technologies International 
Japan G.K,

1-3-3 Higashikawasaki-cho

Chuo-ku 
Kobe-shi, Hyogo, Japan

Warranty

THE MATERIAL CONTAINED IN THIS 

DOCUMENT IS PROVIDED “AS IS,” 

AND IS SUBJECT TO BEING 

CHANGED, WITHOUT NOTICE, IN 

FUTURE EDITIONS. FURTHER, TO 

THE MAXIMUM EXTENT PERMITTED 

BY APPLICABLE LAW, KEYSIGHT 

DISCLAIMS ALL WARRANTIES, 

EITHER EXPRESS OR IMPLIED WITH 

REGARD TO THIS MANUAL AND 

ANY INFORMATION CONTAINED 

HEREIN, INCLUDING BUT NOT 

LIMITED TO THE IMPLIED 

WARRANTIES OF 

MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE. 

KEYSIGHT SHALL NOT BE LIABLE 

FOR ERRORS OR FOR INCIDENTAL 

OR CONSEQUENTIAL DAMAGES IN 

CONNECTION WITH THE 

FURNISHING, USE, OR 

PERFORMANCE OF THIS 

DOCUMENT OR ANY INFORMATION 

CONTAINED HEREIN. SHOULD 

KEYSIGHT AND THE USER HAVE A 

SEPARATE WRITTEN AGREEMENT 

WITH WARRANTY TERMS 

COVERING THE MATERIAL IN THIS 

DOCUMENT THAT CONFLICT WITH 

THESE TERMS, THE WARRANTY 

TERMS IN THE SEPARATE 

AGREEMENT WILL CONTROL.

Technology Licenses

The hardware and/or software 

described in this document are 

furnished under a license and may be 

used or copied only in accordance 

with the terms of such license.

Declaration of Conformity

Declarations of Conformity for this 
product and for other Keysight 

products may be downloaded from 

the Web. Go to 

http://www.keysight.com/go/confor

mity

. You can then search by product 

number to find the latest Declaration 
of Conformity.

U.S. Government Rights

The Software is “commercial 
computer software,” as defined by 

Federal Acquisition Regulation 

(“FAR”) 2.101. Pursuant to FAR 

12.212 and 27.405-3 and 

Department of Defense FAR 

Supplement (“DFARS”) 227.7202, the 

U.S. government acquires 

commercial computer software 

under the same terms by which the 

software is customarily provided to 

the public. Accordingly, Keysight 

provides the Software to U.S. 

government customers under its 

standard commercial license, which 

is embodied in its End User License 

Agreement (EULA), a copy of which 

can be found at 

http://www.keysight.com/find/sweul

a

The license set forth in the EULA 

represents the exclusive authority by 

which the U.S. government may use, 

modify, distribute, or disclose the 

Software. The EULA and the license 

set forth therein, does not require or 

permit, among other things, that 

Keysight: (1) Furnish technical 

information related to commercial 

computer software or commercial 

computer software documentation 

that is not customarily provided to 

the public; or (2) Relinquish to, or 

otherwise provide, the  government 

rights in excess of these rights 

customarily provided to the public to 

use, modify, reproduce, release, 

perform, display, or disclose 

commercial computer software or 

commercial computer software 

documentation. No additional 

government requirements beyond 

those set forth in the EULA shall 

apply, except to the extent that those 

terms, rights, or licenses are 

explicitly required from all providers 

of commercial computer software 

pursuant to the FAR and the DFARS 

and are set forth specifically in 

writing elsewhere in the EULA. 

Keysight shall be under no obligation 

to update, revise or otherwise modify 

the Software. With respect to any 

technical data as defined by FAR 

2.101, pursuant to FAR 12.211 and 

27.404.2 and DFARS 227.7102, the 

U.S. government acquires no greater 

than Limited Rights as defined in FAR 

27.401 or DFAR 227.7103-5 (c), as 
applicable in any technical data.

Safety Notices

CAUTION

 notice denotes a hazard. It 

calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or adhered 

to, could result in damage to the 

product or loss of important data. Do 

not proceed beyond a CAUTION 

notice until the indicated conditions 

are fully understood and met. 

WARNING

 notice denotes a hazard. 

It calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or adhered 

to, could result in personal injury or 

death. Do not proceed beyond a 

WARNING notice until the indicated 

conditions are fully understood and 
met.

Summary of Contents for 16089A

Page 1: ...Operation and Service Manual Keysight 16089A B C Kelvin Clip Leads...

Page 2: ...puter software under the same terms by which the software is customarily provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial lic...

Page 3: ...l Performance Characteristics of 16089B 9 Supplemental Performance Characteristics of 16089C 9 2 Preparation for Use Introduction 11 Initial Inspection 11 16089A 12 16089B 13 16089C 14 Ambient Environ...

Page 4: ...4 Keysight 16089A B C Operation and Service Manual Contents...

Page 5: ...both general and specific information To use the 16089A B C to perform a specific function without having to read the entire manual follow the directions in Using the 16089A B C Using the 16089A B C T...

Page 6: ...direct attachment four terminal pair type test leads that are equipped with two insulated Kelvin clips Three sizes of Kelvin clips are provided The 16089A Kelvin Clip Leads is equipped with two large...

Page 7: ...warrant more than normal safety precautions for operator safety Nevertheless service should be performed only by qualified personnel Electrostatic discharge ESD can damage the highly sensitive microci...

Page 8: ...rformance standards and limits against which the 16089A B C is tested When shipped from the factory the 16089A B C meets the following specifications Maximum dc Bias Voltage 42V peak max Frequency Ran...

Page 9: ...s additional information for the operator Supplemental performance characteristics are not guaranteed Supplemental Performance Characteristics of 16089A Supplemental Performance Characteristics of 160...

Page 10: ...10 Keysight 16089A B C Kelvin Clip Leads General Information Supplemental Performance Characteristics 1...

Page 11: ...hes dents or the like They should also be in perfect electrical condition Verify this by carefully performing an incoming inspection to check the test lead set for signs of physical damage and missing...

Page 12: ...1 Contents of 16089A Description Keysight Part Number Qty RoHS Compliant Replacement Part Qty Kelvin Clip Leads 16089 600011 1 Keysight internal only part number 1 16089 60601 1 Operation and Service...

Page 13: ...Contents of 16089B Description Keysight Part Number Qty RoHS Compliant Replacement Part Qty Kelvin Clip Leads 16089 600021 1 Keysight internal only part number 1 16089 60602 1 Operation and Service M...

Page 14: ...Contents of 16089C Description Keysight Part Number Qty RoHS Compliant Replacement Part Qty Kelvin IC Clip Leads 16089 600031 1 Keysight internal only part number 1 16089 60603 1 Operation and Service...

Page 15: ...95 at 40 C non condensing Connecting the Test Leads for Use Figure 2 4 Connecting the Test Leads Packaging the Test Leads If shipment to a Keysight Technologies service center is required each test le...

Page 16: ...16 Keysight 16089A B C Kelvin Clip Leads Preparation for Use Packaging the Test Leads 2...

Page 17: ...escribes using the test leads and compensation techniques for these test leads Test Leads Features 16089A B C Figure 3 1 16089A B C Test Leads Features 1 Kelvin Clips These are connected to the DUT 2...

Page 18: ...nt s OPEN and SHORT compensation capabilities must be used The procedures are described in the measurement instrument s operation manual Figure 3 2 Making a Short Condition for the 16089B and 16089C W...

Page 19: ...etting according to the LCR meter Impedance Analyzer operation manuals 2 Connect the test leads of 16089A B C to the measurement instrument s UNKNOWN terminals 3 Perform OPEN and SHORT compensation as...

Page 20: ...20 Keysight 16089A B C Kelvin Clip Leads Preparation for Use OPEN and SHORT Compensation 3...

Page 21: ...n for the 16089A 16089B and 16089C Serial Number for Non RoHS Kelvin Clip Leads 16089A MY44100001 MY44199999 16089B MY40100001 MY40199999 16089C MY44100001 MY44199999 or SG44100001 SG44199999 Serial N...

Page 22: ...t number is replaced by the respective RoHS Compliant Replacement Part Once the original support part is depleted please proceed to obtain the RoHS compliant support part 16089A Replaceable Parts Red...

Page 23: ...2 16089B Replaceable Parts Keysight Non RoHS Part Number Description Qty RoHS Compliant Replacement Part Description Qty 16089 60002 Test Leads1 1 The whole unit Keysight internal only part 1 16089B2...

Page 24: ...6089 60603 Kelvin IC Clip Leads 1 16089 04003 Cover Top 1 16089 606033 3 Poka Yoke Design Change RoHS cover top 16089 04603 is not backward com patible with non RoHS fixture REplace the whole fixture...

Page 25: ...Keysight 16089A B C Kelvin Clip Leads 25 Service Replaceable Parts Figure 4 1 Kelvin Clip Connections...

Page 26: ...26 Keysight 16089A B C Kelvin Clip Leads Service Replaceable Parts 4...

Page 27: ...This information is subject to change without notice Keysight Technologies 1999 2020 Edition 7 January 2020 16089 90030 16089 90030 www keysight com...

Reviews: