background image

Keyscan Inc. A Member of the Kaba Group 

18 

Specifications 

Input Power Requirements 

Powered through control board (NETCOM6P 140 mA + control board 130 mA = 270 mA  

Network  

RJ45 (10/100 Base-T) Ethernet 
LAN/ WAN (TCP/IP protocol—port 3001) 

Agency Approvals—Ethernet Socket 

Complies with Class B limits of EN 55022: 1998 Direct & Indirect ESD. 
Complies with EN55024:1998 

Dimensions 

1 9/16” x 1 15/16” (41 mm x 49 mm) 

Environmental 

Suitable for industrial and commercial applications. 
Operating temperatures: 5

0

 C to 70

0

 C (41

0

 F to 158

0

 F) 

Encryption 

256 – bit AES Rijndael encryption 
For more information on encryption, visit 
http://www.bis.doc.gov/encryption/default.htm 
http://www.bis.doc.gov/policiesandregulations/regionalconsiderations.htm 

RJ45 Ethernet (Xport) LED States 

The RJ45 Ethernet terminal has two bi-colour LEDs: 

Link LED (left side) 

Activity LED (right side) 

Amber – flashing 

10 Mbps 

Amber – flashing 

Half-duplex 

Green – flashing 

100 Mbps 

Green – flashing 

Full-duplex 

 

Summary of Contents for NETCOM6P

Page 1: ...license involves installing and configuring reverse network encrypted communication software at a host location and installing hardware components at a remote location You must coordinate certain set...

Page 2: ...2345678 12345678 12345678 12345678 Control Board Reverse Network Programming Host Router EndPoint External IP 24 48 52 134 Port 3001 May also include an alternate host router external IP address if av...

Page 3: ...Same encryption key bit setting as host location Figure 2 Example of LAN closed with no public exposure Host Location Remote Access Control Location LAN Encrypted NETCOM6P Internal Static IP 192 168...

Page 4: ...ch NETCOM6P unless using a DHCP server Space is provided to record the address settings at the back Ensure you install the latest Keyscan NETCOM Program Tool utility on the enclosed CD on a laptop or...

Page 5: ...rse Network Settings Communication Bits Second Mode Switch Settings 0 Off 1 On 9600 Reverse network 1 2 3 1 0 0 57 600 Reverse network 1 2 3 1 0 1 The recommended setting is 57 600 Steps to Set the Co...

Page 6: ...n Key The encryption key for the NETCOM6P must consist of one of the following bit settings 32 characters 128 bit 48 characters 192 bit or 64 characters 256 bit Characters can be as follows in any com...

Page 7: ...al enclosure to discharge body static 2 Disconnect the ACU control board from the power 3 Using a 4 Phillips screwdriver unfasten the 6 screws holding the ACU protective cover Remove the cover and set...

Page 8: ...l board to the laptop or PC as illustrated in Figure 5 If using the USB SER adaptor see Figure 6 Be sure the USB SER adaptor has been configured before programming 7 Apply power to the ACU control boa...

Page 9: ...iation unless the IT administrator gives a specific setting If the NETCOM device experiences network communication difficulties you may have to alter the Ethernet Connection Type from automatic negoti...

Page 10: ...ing for a NETCOM reset or power cycle Momentarily place a jumper on the control board s J6 RESET pins then remove the jumper or press and release the S1 switch 28 Wait while the NETCOM Program tool ut...

Page 11: ...llowing steps depending on the PC109x version of control board J16 Jumpers Remove the jumpers from J16 pins F G And then place a jumper on J6 momentarily to reset the control board and then remove the...

Page 12: ...e IP address is correct go to the next step If the IP address is incorrect repeat steps 11 to 14 14 As an option you can set a secondary IP address and or set an override port number as outlined below...

Page 13: ...eeping 25 After the control board and the NETCOM have been programmed and connected to the network confer with the host location to confirm the reverse network software installation procedures have be...

Page 14: ...Programming Connections RJ45 Terminal Jack NETCOMP RESET Control Board PC 109x Cut view with ACU protective cover removed Common AUX Inputs E CPB CB MODULE COM4 AUX Inputs D Common IOCB COM1 NETCOMP p...

Page 15: ...ontrol Board PC 109x Cut view with ACU protective cover removed Common AUX Inputs E CPB CB MODULE COM4 AUX Inputs D Common IOCB COM1 NETCOMP plugs into M1 on control board RS 232 COM4 GND TD RD DCD DT...

Page 16: ...PC109x or higher ACU Control Board PC 10 100 Base T Cable Control Board NETCOM2P or NETCOM6P to network Host PC with Communication Manager Parts List to network 10 or 100 Base T Current Draw ACU NETC...

Page 17: ...ation IP address If the remote location has a router or end point device verify inbound outbound communication with the correct port settings Host Location Has the Reverse Network license been registe...

Page 18: ...6 x 1 15 16 41 mm x 49 mm Environmental Suitable for industrial and commercial applications Operating temperatures 50 C to 700 C 410 F to 1580 F Encryption 256 bit AES Rijndael encryption For more inf...

Page 19: ...NETCOM6P ACU RN Encrypted Installation Guide 19 This page is intentionally blank...

Page 20: ...Required fields for device configuration with software If other than Automatic Negotiation Keyscan Inc 901 Burns St E Whitby Ontario Canada L1N 0E6 1 888 539 7226 toll free Canada USA 905 430 7226 el...

Reviews: