Keyscan NETCOM6P Installation Manual Download Page 14

Keyscan Inc. A Member of the Kaba Group 

14 

NETCOM6P Serial Programming Connections  

Figure 5 illustrates serial programming connections from the PC or laptop to the NETCOM6P 
via M1 on the control board using the enclosed data cables. 

If the PC or laptop does not have a serial port, use Keyscan's optional USB-SER adaptor. 

Figure 5 - Serial Programming Connections 

R

J

4

5

T

e

rm

in

a

l

J

a

c

k

N

E

T

C

O

M

P

R

E

S

E

T

Control Board

(PC 109x) 

Cut view with ACU 

protective cover removed.

Common

AUX Inputs - E

CPB/CB MODULE

(COM4)

AUX Inputs - D

Common

IOCB (COM1)

NETCOMP plugs into M1 on 

control board.

For programming a NETCOM2P or NETCOM6P
J16 

– jumpers F & G - ON

Or 
S2 

– DIP switches 7 & 8 - ON.

RS-232  (COM4)

GND

TD

RD

DCD

DTR

CTS

PC or laptop with Keyscan 

NETCOM Program Tool 

Utility.

Green

Red

Black

Serial Data 

Cable

with loose 

conductors

TAMPER TB3 
SWITCH

+

-

KI-00253E-08-13

 

Temporary connections for programming only. 

Summary of Contents for NETCOM6P

Page 1: ...license involves installing and configuring reverse network encrypted communication software at a host location and installing hardware components at a remote location You must coordinate certain set...

Page 2: ...2345678 12345678 12345678 12345678 Control Board Reverse Network Programming Host Router EndPoint External IP 24 48 52 134 Port 3001 May also include an alternate host router external IP address if av...

Page 3: ...Same encryption key bit setting as host location Figure 2 Example of LAN closed with no public exposure Host Location Remote Access Control Location LAN Encrypted NETCOM6P Internal Static IP 192 168...

Page 4: ...ch NETCOM6P unless using a DHCP server Space is provided to record the address settings at the back Ensure you install the latest Keyscan NETCOM Program Tool utility on the enclosed CD on a laptop or...

Page 5: ...rse Network Settings Communication Bits Second Mode Switch Settings 0 Off 1 On 9600 Reverse network 1 2 3 1 0 0 57 600 Reverse network 1 2 3 1 0 1 The recommended setting is 57 600 Steps to Set the Co...

Page 6: ...n Key The encryption key for the NETCOM6P must consist of one of the following bit settings 32 characters 128 bit 48 characters 192 bit or 64 characters 256 bit Characters can be as follows in any com...

Page 7: ...al enclosure to discharge body static 2 Disconnect the ACU control board from the power 3 Using a 4 Phillips screwdriver unfasten the 6 screws holding the ACU protective cover Remove the cover and set...

Page 8: ...l board to the laptop or PC as illustrated in Figure 5 If using the USB SER adaptor see Figure 6 Be sure the USB SER adaptor has been configured before programming 7 Apply power to the ACU control boa...

Page 9: ...iation unless the IT administrator gives a specific setting If the NETCOM device experiences network communication difficulties you may have to alter the Ethernet Connection Type from automatic negoti...

Page 10: ...ing for a NETCOM reset or power cycle Momentarily place a jumper on the control board s J6 RESET pins then remove the jumper or press and release the S1 switch 28 Wait while the NETCOM Program tool ut...

Page 11: ...llowing steps depending on the PC109x version of control board J16 Jumpers Remove the jumpers from J16 pins F G And then place a jumper on J6 momentarily to reset the control board and then remove the...

Page 12: ...e IP address is correct go to the next step If the IP address is incorrect repeat steps 11 to 14 14 As an option you can set a secondary IP address and or set an override port number as outlined below...

Page 13: ...eeping 25 After the control board and the NETCOM have been programmed and connected to the network confer with the host location to confirm the reverse network software installation procedures have be...

Page 14: ...Programming Connections RJ45 Terminal Jack NETCOMP RESET Control Board PC 109x Cut view with ACU protective cover removed Common AUX Inputs E CPB CB MODULE COM4 AUX Inputs D Common IOCB COM1 NETCOMP p...

Page 15: ...ontrol Board PC 109x Cut view with ACU protective cover removed Common AUX Inputs E CPB CB MODULE COM4 AUX Inputs D Common IOCB COM1 NETCOMP plugs into M1 on control board RS 232 COM4 GND TD RD DCD DT...

Page 16: ...PC109x or higher ACU Control Board PC 10 100 Base T Cable Control Board NETCOM2P or NETCOM6P to network Host PC with Communication Manager Parts List to network 10 or 100 Base T Current Draw ACU NETC...

Page 17: ...ation IP address If the remote location has a router or end point device verify inbound outbound communication with the correct port settings Host Location Has the Reverse Network license been registe...

Page 18: ...6 x 1 15 16 41 mm x 49 mm Environmental Suitable for industrial and commercial applications Operating temperatures 50 C to 700 C 410 F to 1580 F Encryption 256 bit AES Rijndael encryption For more inf...

Page 19: ...NETCOM6P ACU RN Encrypted Installation Guide 19 This page is intentionally blank...

Page 20: ...Required fields for device configuration with software If other than Automatic Negotiation Keyscan Inc 901 Burns St E Whitby Ontario Canada L1N 0E6 1 888 539 7226 toll free Canada USA 905 430 7226 el...

Reviews: