2
3
➔
HDCP 2.2:
Compliancy up to HDCP 2.2 and backward compliant
➔
Bandwidth:
TMDS bandwidth 10.2 Gbps
➔
Deep Color Support:
Up to UHD/4K 30Hz 4:2:2/12 bits or 60Hz 4:2:0/8 bit
➔
HDMI
®
and HDCP Licensing:
Fully licensed and compatible with HDCP 2.2 and
HDMI latest technology such as 4K/UHD 4:2:0/8bit at 60f/s
➔
EDID Control:
Internal library features 15 default EDID configurations and
native EDID data from Output/Display devices connected via Rx
➔
Full Buffer System
™
:
Manages TMDS re-clocking / signal re-generation,
HDCP authentication with source & display, EDID Control handshake,
and Hot Plug control
➔
IR Sensor:
Wall-plate collects line-of-sight IR from remote(s) without
external IR wiring
➔
RS-232:
Bi-Directional control to/from Tx and Rx unit
➔
Unit Control Mode:
Provides RS-232 control and status of/from Tx unit
➔
Lossless compressed digital audio:
Support for Dolby
®
TrueHD,
Dolby
®
Digital Plus, Dolby Atmos
®
, and DTS-HD Master Audio
™
➔
CEC Support:
For inter-device control between input and output HDMI channel
➔
I2C Communication:
EDID and HDCP authentication to Display and Source
➔
Control System Support:
Fully controllable by all RS-232 supported control
systems via open API: Compass Control
®
Pro, AMX
®
, Crestron
®
, KNX
®
, RTI
®
,
Savant, URC
®
, Leviton
®
etc.
Accessories
➔
24V 1.67A DC power supply (qty 1)
➔
Aluminum decora plate (qty 1)
➔
Decora mounting screws with flat head (qty 4)
➔
Gang-box mounting screws (qty 4)
➔
Mounting bracket (qty 2)
➔
IR Emitter (qty 1)
➔
3-pin phoenix terminal (qty 2)
Quick Setup Guide
Step 1:
Ensure that all desired functionality is achieved before installing the
Tx wall plate
Step 2:
Find a safe and convenient location to mount or place the Rx unit
Step 3:
Begin with the Tx, Rx units and all input/output devices turned off with
power cables removed
Step 4:
Connect HDMI and/or VGA + audio source to the input port of the Tx unit
Step 5:
Connect HDMI display to the output port of Rx unit
Step 6:
Connect CAT5e/6 cabling to Tx and Rx units.
Use 568-B standard termination on both ends.
Step 7:
If controlling external devices, connect IR emitter and sensor, and RS-232
cabling as needed
Step 8:
BEFORE
connecting power supply to power outlet, secure power wiring
into phoenix connector and insert into Tx or the Rx units
Step 9:
AFTER
all connections are made, plug-in power supply to power outlet
Step 10:
Power on input/output devices
Step 11:
Choose desired source using Input Select button
Installation and Operation
Before permanently securing the unit for final installation, test for proper operation
of the unit and cables in your system. It is recommended that you leave enough
ventilation space to provide sufficient airflow and cooling.
You MUST use the Power Supply provided with your unit or you VOID
the Key Digital
®
Warranty and risk damage to your unit and associated
equipment.
Summary of Contents for KD-SX440WP