28
EN
6 - INSIGHTS - ADVANCED MENU
Function
Default
Min
Max
Value
1.
650
100
700
Opening speed (mm/sec)
2.
240
100
600
Closure speed (mm/sec)
3.
25
1
30
Opening deceleration speed (mm/sec)
4.
20
1
30
Closure deceleration speed (mm/sec)
5.
8
2
50
Ramp deceleration time in opening
6.
3
2
50
Ramp deceleration time in closing
7.
200
50
300
Approach space at opening
8.
100
50
300
Approach space at closing
9.
10
1
100
Force on obstacle
A.
2
1
60
Automatic closing (sec)
B.
75
50
99
Percentage of partial opening run (1 to
100%)
C.
0
0
15
Card Address (0 to 15)
D.
0
0
1
Safety elastic
0 = not present
1 = present
E.
0
0
2
If door is forced (Pull & Go)
0=resistance to force
1 = opens
2 = stays open
F.
0
0
4
If there is power outage
0 = functioning continues
1=opens even if locked
2=closes and locks
3=opens only if unlocked
4=closes but does not lock
G.
0
0
4
If battery is dead
(can be displayed only if parameter P=1)
0 = functioning continues
1=opens even if locked
2=closes and locks
3=opens only if unlocked
4=closes but does not lock
H.
1
0
1
Direction of motion( )
0=right hand opening
1=left hand opening
N.B. Check hook dragging carts
mechanical part
J.
15
0
59
Voltage applied when door stopped
L.
0
0
2
FOTO Surveillance
0 = not monitored
1=one monitored device
2=two monitored devices
N.
0
0
2
FOTO RALL Surveillance
0 = not monitored
1=one monitored device
2=two monitored devices
O.
0
0
2
STOP Surveillance
0 = not monitored
1=one monitored device
2=two monitored devices
P.
0
0
1
Battery presence
0 = test disabled
1 = test enabled
R.
0
0
1
Lock if R.INT or R.EXT
0 = Normal functioning
1= RINT or REXT closed door locks
T.
0
0
1
Sixth manual selector position
(LOGO KEY)
0 = Partial opening
1=REXT(external radar active)
U.
0
0
9
Duration opening START
0 = step-step
1 to 9 (in tens of seconds)
Y.
0
0
1
Interlock
0 = disabled
1 = enabled
To change a parameter, oand- then save holding down the OK button for at least 2 seconds until you hear a beep.
Holding down the M button for at least 2 seconds until you hear a beep shows the viewing mode again.
6.1 - Change parameters
Holding down the M button for at least 2 seconds until you hear a
beep displays and allows for editing of the following operating
parameters:
Please note: The function change from 1 to 9 involves the performingof
2 cycles of self-regulation during which the display shows “
”