Kett AN-920 Operating Manual Download Page 7

7

2-3. Accessories

Spare fuse

Sampling cup

Power cable

Sample case ×2

Operating manual

Storage container

Standard sample

Storage container

Standard sample (brown rice/milled rice) ×1 each

(Stored in the storage container)

Summary of Contents for AN-920

Page 1: ...NIR Rice Composition Analyzer AN 920 Operating Manual Thank you for purchasing this product Please read the operating manual carefully and use this product properly...

Page 2: ......

Page 3: ...ts of Main Unit 6 2 3 Accessories 7 3 SPECIFICATIONS 8 4 DESCRIPTION OF OPERATION KEYS 9 5 EASY OPERATION GUIDE 10 6 ADJUSTMENT 12 7 SETUP 13 8 OTHERS 16 8 1 Printer Output 16 8 2 Replacing Fuses 16 8...

Page 4: ...a place where explosive inflammable gas or liquid substance exists Otherwise it may cause explosion fire or electric shock etc Do not use other than rated power supply voltage If overvoltage is applie...

Page 5: ...le or other cables never pull on the cord or cable and instead hold the plug or cable connector Do not install the unit in a place where handling the power cable and connectors or turning the power sw...

Page 6: ...e a tungsten lamp is used High measurement accuracy can be achieved by adopting a method in which the transmitted light from the sample is detected after being diffracted into 600 to 1100 nm by a spec...

Page 7: ...ccessories Spare fuse Sampling cup Power cable Sample case 2 Operating manual Storage container Standard sample Storage container Standard sample brown rice milled rice 1 each Stored in the storage co...

Page 8: ...ns and weight 230 W 400 D 250 H mm 8 5 kg Accessories Power cable Fuse Sample case 2 Sampling cup Standard sample brown rice milled rice 1 each storage container standard sample operating manual Optio...

Page 9: ...he value 7 SETUP P 13 14 15 Display date time communica tion light intensity reset and user switching can be set 6 ADJUSTMENT P 12 Adjustments are required before starting the measurement There are tw...

Page 10: ...ommended to keep the tempera ture of the sample and the environ mental temperature close Clean the sample case If the window of the sample case is not clean or significantly scratched adjustment or me...

Page 11: ...ver open the cover 15 The measurement result will be displayed Pressing the MEASURE key in this screen will enable a new measurement Pressing the Home key will restore the initial screen The average o...

Page 12: ...anually calculated Change the value with keys and then press the Enter key 4 Pressing the Home key will restore the initial screen Procedure 1 Press the Adjustment key 2 The measured value of the stan...

Page 13: ...he Setup key 2 Press the DISPLAY key 3 For each item press to display and to hide 4 To set the display range press the value Change the value with keys and press the Enter key When Protein CM is set t...

Page 14: ...When the tungsten lamp is blown replace the lamp in the following procedure Make sure to purchase the new lamp from Kett Do not use other lamp than specified one While the power is turned on the lamp...

Page 15: ...asurement Calibration curve selection Bias adjustment Display setting Date Time setting Communica tion setting Light intensity resetting User addition Administrator User Guest 3 Switching the user Pro...

Page 16: ...easurement Sample is too dark bright Instrument temperature is too low high Sample temperature is too low high A D Converter Error Replace lamp The following messages may be displayed during initializ...

Page 17: ...refrigerator Never store the sample in the freezer The sample will be frozen Other than the appropriate storage it may cause a change to the standard value The validation period indicated on the stand...

Page 18: ......

Page 19: ......

Page 20: ...and parts depicted in this user manual may not appear exactly as their actual counterparts but this does not affect their operation or functionality This user manual was intended to be written as clea...

Reviews: