8
Installation and Servicing
SECTION 1 - GENERAL
30
Gas supply
2H - G20 - 20mbar
Gas Supply Connection
15mm copper compression
Injector Size
(mm)
4.65
Flow Connection
Central Heating
22mm copper compression
Return Connection
Central Heating
22mm copper compression
Flue Terminal Diameter
mm (in)
50 (2)
Average Flue Temp-Mass Flow Rate
69
o
C - 13g/s
Maximum Working Pressure (Sealed Systems)
bar (lb/in
2
)
2.5 (36.3)
Electrical Supply
230 V ~ 50 Hz.
Power Consumption
W
100
Fuse Rating
External : 3A Internal : T4A HRC L250 V
Water content
litre (gal)
1.2 (0.26)
Packaged Weight
kg
31.6
Maximum Installation Weight
kg
26.2
Boiler Casing Size
Height
mm
700
Width mm
395
Depth
mm
278
Table 1 - General Data
Note.
Gas consumption is calculated using a
calorific value of 38.7 MJ/m
3
(1038 Btu/ft
3
) gross or
34.9 MJ/m
3
(935 Btu/ft
3
) nett
To obtain the gas consumption at a different calorific
value:
a.
For l/s
- divide the gross heat input (kW) by the
gross C.V. of the gas (MJ/m
3
)
b. For Btu/h
- multiply the gross heat input (kW) by
26.8
c.
For ft
3
/h
- divide the gross heat input (Btu/h) by
the gross C.V. of the gas (Btu/ft
3
)
d.
For m
3
/h
- multiply l/s by 3.6
Key to symbols
GB
= United Kingdom
IE
= Ireland
(Countries of destination)
PMS
= Maximum operating pressure of water
C
13
C
53
= A room sealed appliance designed for connection via ducts to a horizontal
terminal, which admits fresh air to the burner and discharges the products
of combustion to the outside. The fan is up stream of the combustion
chamber.
I
2H
= An appliance designed for use on 2nd Family gas, Group H only.
* The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by a notified body.
30
MIN
MAX
Boiler Input :
Boiler Input ‘Q’ Nett CV
kW
6.1
30.4
Gross CV
kW
6.7
33.7
Gas Consumption
m
3
/h
0.622
3.135
(ft
3
/h) (22)
(111)
Boiler Output :
Non Condensing kW
6.1
30.3
70
o
C Mean Water temp.
Condensing
kW
6.4
31.0
40
o
C Mean Water temp.
Seasonal efficiency* SEDBUK 2005
91.1%
Seasonal efficiency* SEDBUK 2009
89.6%
NOx Classification
CLASS 5
Table 2 - Performance Data - Central Heating