Installation
40 / 148
2017/10
010-993
Date / Time
• Set the respective flashing figure in date and time and confirm with OK. Following the last entry, the menu
item
Product type
is displayed.
Product type
• Select Aqualift Mono or Duo pumping station and confirm with OK, the menu item
System variant
is displayed
.
System variant
• Select the relevant system variant and confirm with OK, the menu item
Performance quantity
appears.
Power quantity
• Select the relevant power quantity and confirm with OK, the menu item
Maintenance date
appears.
Maintenance interval
• Select the required maintenance period or enter accordingly and confirm with OK, the menu item
System info
appears, initialisation is complete.
4.7.2 Functional check
Follow the safety instructions in chapter 3.
• Switch off the pumping station (if necessary, disconnect the mains power plug)
• If necessary, Open the cover of the system tank (inspection chamber)
• Fill the system tank with water until the switching level of the system is exceeded
(at least until the pumps are completely covered with water).
• Switch on the pumping station (if necessary, plug in the mains plug).
– If installed, check whether the control unit is initialised
– Pump starts up automatically
– The pump pumps out water until the switching-off level is reached (pump head visible once again)
– Pump switches off automatically
• If installed, check the control unit for errors/alarm signals. In case of errors/alarm signals, please follow the
instructions in Chapter 7.
Summary of Contents for Aqualift S XL
Page 30: ...Introduction 30 148 2017 10 010 993 1 3 How it works Aqualift Comfort Ill 2...
Page 145: ...Deklaracja zgodno ci DOP 145 148 2017 10 010 993 9 Deklaracja zgodno ci DOP...
Page 146: ...Deklaracja zgodno ci DOP 146 148 2017 10 010 993 x...
Page 147: ...Notizen 147 148 2017 10 010 993 10 Notizen...
Page 148: ...Notizen 148 148 2017 10 010 993...