Troubleshooting
46 / 148
2017/10
010-993
7
Troubleshooting
All work exceeding the activities described in the Operation chapter may only be carried out by skilled
personnel (see 3.2).
• Follow the instructions described in 6.1 and carry out if necessary
Error
Possible cause
Remedial measure / Chapter
Battery fault
Battery is missing, is defective or voltage
is too low
Check battery connection, if necessary
replace battery.
Power outage
Power supply has failed
None, general power outage
Control unit fuse faulty
Determine the reason for the fuse
failure and possibly replace fuse
Device fuse has failed
Check fuse
Main switch faulty
Check main switch
Mains supply cable interrupted
Check mains supply cable
Level fault
Illogical sequence of levels detected
inform Customer Services
Alarm level exceeded
Power outage
Restore power supply
Wastewater pump has overheated,
winding temperature switch has triggered
Self-resetting when the motor cools
down. Replace pump if the temperature
fault persists.
Level sensor (float switch) jammed by
deposits
Clean the pumping station / 6.4.2
Wastewater pump is defective
Inform customer service
Limit running time
Pump is running too long per pumping
operation
- Check design and if necessary inform
customer service
- Pump overrun too long / set shorter
(potentiometer in control unit)
Limit number of operations
Pump running too frequently within a
short time
Check design, if necessary inform
customer service
Vent opening of the pump
clogged
Possible malfunctions of the pump
Remove obstruction
Summary of Contents for Aqualift S XL
Page 30: ...Introduction 30 148 2017 10 010 993 1 3 How it works Aqualift Comfort Ill 2...
Page 145: ...Deklaracja zgodno ci DOP 145 148 2017 10 010 993 9 Deklaracja zgodno ci DOP...
Page 146: ...Deklaracja zgodno ci DOP 146 148 2017 10 010 993 x...
Page 147: ...Notizen 147 148 2017 10 010 993 10 Notizen...
Page 148: ...Notizen 148 148 2017 10 010 993...