40
6. Help during malfunctions
- Check power supply and
fuse / breaker
- Repair to be handled by
KESSEL Customer Service
Only
- Check pressure switch
(see Section 4.5) or repair
with KESSEL Customer
Service
- Clean ventilation pipe of
the pump
Clean pump(s) – (follow
instructions in Section 1.1)
- Clean pump(s),
Replace intake flange
- Replace impeller and or
cutting / macerating as-
sembly
- Clean ventilation pipe
- Clean outlet pressure pipe
- Clean inlet suction pipe
- Replace backwater flap
- Clean outlet pressure pipe/
check to make sure the
entire system is watertight
- No power to unit
- Power chord damaged
- Pressure switch defective
- Ventilation pipe blocked
Debris or solids has jammed
between the impeller and the
suction flange
- Suction basket damaged or
worn
- Impeller damaged or worn /
cutting assembly (macerator)
damaged or worn
- Ventilation pipe blocked
- Pressure outlet blocked
- Suction inlet blocked
- Backwater flap defective / not
watertight
- Pressure switched blocked or
damaged
Pump doesnʼt start
Impeller blocked
Reduced pumping
performance
Pump is running without
wastewater being present
Malfunciton Possible Cause Remedial actions
Summary of Contents for 28701
Page 19: ...19 9 Konformit tserkl rung...
Page 20: ...20 Notizen...
Page 22: ...22 Notizen...
Page 43: ...43 9 Conformity Statement...
Page 44: ...44 Notes...
Page 46: ...46 Notes...
Page 67: ...67 9 D claration de conformit...
Page 68: ...68 Note...
Page 70: ...70 Note...
Page 72: ......
Page 91: ...91 9 Dichiarazione di conformit...
Page 92: ...92 Note...
Page 94: ...94 Note...
Page 115: ...115 9 Conformiteitsverklaring...
Page 116: ...116 Notizen...
Page 118: ...118 Note...
Page 139: ...139 9 Deklaracja zgodno ci...
Page 140: ...140 Notatki...
Page 142: ...142 Notatki...