2.0 PRODUCT INFORMATION
CLEARANCE (minimum) TO COMBUSTIBLES
Top of Supply Plenum
1”
(25 mm)
Front (Maintenance)
24”
(610 mm)
Rear (Maintenance)
24”
(610 mm)
Side – Non-Access
1”
(25 mm)
Side – Access maintenance
24”
(610 mm)
Flue Pipe
9”
(229 mm)
Floor (Can be installed directly on combustible or non-combustible)
Furnaces for indoor installation on combustible flooring shall not be installed directly
on carpeting, tile or other combustible material other than wood flooring.
DRAFT PRESSURE
Breech draft pressure
-0.01” wc minimum
AIR/BLOWER DATA
Maximum external static pressure
0.5” wc
Maximum cooling unit capacity
3.0 tons & 5.0 Tons
Maximum air temperature rise
See pages 19,20 and 33
High Limit temperature
185°F
Thermostat anticipator
See thermostat instructions
MOTOR/BLOWER
Gemini 3T / Eclipse 3T: 1/2 hp 4 Speed / G10-8 DD or 1/2 hp ECM / G10-8
Gemini 5T: ¾ hp / G12-10 DD or ¾ hp ECM / G12-10 DD
FAN/HIGH LIMIT CONTROL
Honeywell ST9103A1028 Fan Center & Thermo-Disk (7” stem)
THERMOSTAT
Any wall thermostat
ELECTRICAL – 120 Volts, 60 Hz
Canada
Less than 12 amps. circuit protection 15 amps.
USA
13.3 amps, circuit protection 20 amps.
FLUE-PIPE CONNECTION
5” Chimney
AIR FILTERS
Gemini 3T / Eclipse 3T : 20” x 20” x 2” non pleated UL approved
Gemini 5T Rear: 20” x 20” x 2” & 15” x 20” non pleated UL approved
Gemini 5T Front: Two 15” x 20” non pleated UL approved