54
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put the 2 bridges between terminal L1, L2 and L3, the 3rd between N1 and N2.
Attach the earth to the terminal “earth”, the neutral N to terminals N1 or N2, the Phase L to one of the
terminals L1, L2 or L3.
Biphase
400V~2P+N
Put the 1st bridge between terminal L1 and L2, the 2nd between N1 and N2.
Attach the earth to the terminal “earth”, the neutral N to terminal N1 or N2, the Phase L1 to the terminals
L1 or L2 and the Phase L2 to the terminal L3.
Triphase
400V~3P+N
Put a bridge between terminal N1 and N2.
Attach the earth to the terminal “earth”, the neutral N to terminal N1 or N2, the Phase L1 to the terminal
L1 and the Phase L2 to the terminal L2 and the Phase L3 to the terminal L3.
CAUTION!
Frequent loosening and screwing of the screws on the connection box risks damaging
the efficiency of the tightness once screwed. It is therefore advisable to keep screwing
and unscrewing to a minimum. Ensure that the cables are correctly inserted and tightly
screwed down. 4 weeks after installation, be sure to tighten again the screws in the terminal block.
We cannot be held responsible for any incident resulting from incorrect connection or which could
arise from the use of an appliance which has not been earthed or has been equipped with a faulty
earth connection.
Mains
Connection
Cable diameter
Cable
Protection
calibre
230V~ 50/60Hz
1 Phase + N
3 x
4
mm²
H 05 VV - F
40
A *
400V~ 50/60Hz
2 N
4 x
2
,5 mm²
H 05 RR - F
25
A *
CAUTION!
This appliance must only be connected to a network 230 V~ 50/60 Hz.
Always connect the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
Connection of the hob
400V~ 50/60Hz
3
N
5
x 1,5 mm²
H 05 RR - F
16 A *